rich a9980648bf sb-lora: correct U1-U7 rotations in CPL for JLC part models
Checked in JLC's placement preview: U1, U2, U4 needed a 90 deg clockwise
turn (270) and U3, U5-U7 a 180 deg turn for pin 1 to land on the pin-1
pad. Y1 and D1 were already correct.