Remove unrelated ecosystem comparisons and software citations while retaining hardware links, measured model names, and required license notices. Preserve stock-peer runners and tests in a verified local validation package. Keep shared Companion USB transport in the firmware repository for the raw-radio sweep and OTA seeder, with focused CI coverage. Restore missing hosted documentation links.
304 lines
17 KiB
Markdown
304 lines
17 KiB
Markdown
<!-- meshcore-hosted-doc-link:start -->
|
|
<p class="meshcore-hosted-doc-link"><a href="https://mikecarper.github.io/MeshCore/solarxiao_power/">View this page on MeshCore Docs</a>.</p>
|
|
<!-- meshcore-hosted-doc-link:end -->
|
|
|
|
# SolarXiao carrier profiles, MPPT and battery controls
|
|
|
|
SolarXiao Repeater and QSPI OTA Room Server firmware support the CN3791 Base,
|
|
older BQ24650 Advanced and LTC4162/INA260 MPPT carriers in Full and Reduced builds.
|
|
Use USB CLI or the
|
|
authenticated administrator CLI over LoRa. Ship mode and
|
|
saved-policy reset require local USB. Commands do not change RF settings.
|
|
|
|
## Automatic detection and manual overrides
|
|
|
|
There are three power profiles: `auto`, `basic` and `mppt`. Base and Advanced
|
|
share `basic` because their onboard power telemetry and software controls are
|
|
the same; their different analog charger designs require no different driver.
|
|
The default is `auto` when no carrier selection has been saved. Saved MPPT
|
|
selections remain manual overrides, and saved Base/Advanced selections load as
|
|
`basic`. Use `set solar.board auto` to enable detection on such an installation.
|
|
The firmware environment, hardware/OTA identity and flash layout are unchanged.
|
|
|
|
```
|
|
get solar.board
|
|
set solar.board auto
|
|
get solar
|
|
get solar capabilities
|
|
get solar readings
|
|
get solar history
|
|
```
|
|
|
|
Auto mode checks the INA260 manufacturer's ID (`0xfe = 0x5449`) and device ID
|
|
(`0xff & 0xfff0 = 0x2270`) at carrier address `0x40`. An address ACK alone is not
|
|
enough: another device such as INA219 can share that address. Detection only
|
|
reads identity registers; it does not configure/reset either chip. The first
|
|
probe occurs in the loop after initialization, then retries every five seconds
|
|
until a valid identity is found. A positive result identifies MPPT for these
|
|
carrier designs and is retained until reboot or a new board selection.
|
|
Temporary communication loss does not relabel a previously detected MPPT.
|
|
|
|
Without a verified INA260, auto reports `self-only` and keeps retrying. It does
|
|
not claim to distinguish Base from Advanced: neither has a digital identity,
|
|
and missing responses can also mean an MPPT power/bus fault. Charger access,
|
|
saved-override replay and native carrier telemetry stay blocked until a valid
|
|
INA260 identity is found. XIAO self readings remain available throughout.
|
|
The MPPT carrier's INA260 was previously read with USB power only; detection
|
|
does not require the LTC4162 charger to respond at SOLAR/VIN.
|
|
|
|
Manual settings are available when the physical carrier is known:
|
|
|
|
| Setting | Behavior |
|
|
| --- | --- |
|
|
| `set solar.board auto` | Verify INA260 before enabling MPPT; otherwise self-only, retrying. |
|
|
| `set solar.board basic` | Base/Advanced self battery voltage and MCU temperature; no native I2C access. |
|
|
| `set solar.board mppt` | Enable native access without requiring INA260 detection; existing charger write identity checks still apply. |
|
|
|
|
Legacy `base` and `advanced` command values are compatibility aliases for
|
|
`basic`; they are not separate modes. Readbacks and help use the three canonical
|
|
names. Existing Base/Advanced records load as `basic` without being rewritten;
|
|
new Basic saves use the original Advanced record value, preserving the same
|
|
self-only behavior across upgrades.
|
|
|
|
For Base or Advanced, `basic` reports the common hardware capabilities and live
|
|
XIAO battery ADC and processor temperature. It does not claim which analog
|
|
charger is fitted.
|
|
The existing self telemetry stays on channel 1, with voltage and temperature as
|
|
different LPP types. It adds no invented charger flags, current, watts, battery
|
|
NTC temperature or panel measurements. `get solar battery` aliases the self
|
|
readings; the MCU temperature is not a battery or charger temperature.
|
|
If a node already reports battery voltage and MCU temperature on channel 1,
|
|
this profile adds no further physical measurements. It adds carrier detection,
|
|
manual overrides and capability reporting; the voltage/temperature history commands
|
|
also already exist in builds that include telemetry history.
|
|
|
|
The [2025 Base Standard schematic](https://github.com/wehooper4/Meshtastic-Hardware/blob/main/XaioSeries/SolarXaio/Base/Standard/Schematic_SolarXaio_Base_2025-10-23.pdf)
|
|
uses a CN3791 analog charger with no digital interface or INA monitor. Battery
|
|
voltage reaches the XIAO BAT input. Charge status drives an LED, and the other
|
|
charger signals are not connected to XIAO measurement/control inputs. Base
|
|
therefore needs no extra telemetry driver: only self battery voltage and MCU
|
|
temperature are available, just like Advanced. Base Lite publishes a README
|
|
but no schematic, so its exact connections are not independently qualified here.
|
|
|
|
The [2025 Advanced schematic](https://github.com/wehooper4/Meshtastic-Hardware/blob/main/XaioSeries/SolarXaio/Advanced/Standard/Schematic_SolarXaio_ADV_2025-10-23.pdf)
|
|
has no INA monitor or digital charger interface. Charger status pins drive LEDs,
|
|
NTC goes only to the charger, and current/voltage/MPP setpoints use hardware
|
|
resistors, switches and a solder jumper. An OTA update cannot measure those
|
|
signals or change those setpoints without additional hardware connections.
|
|
|
|
Manual Basic mode suppresses native LTC4162/INA260 polling, register reads/writes,
|
|
replay and native measurements on channels 2..13. `get mppt`, `set mppt ...` and
|
|
`mppt ...` explain that Basic Base/Advanced layouts have no digital charger interface.
|
|
Pending auto mode only probes INA260 identity; it does not access the charger.
|
|
The generic sensor scanner still reserves native addresses 0x40 and 0x68, so it
|
|
cannot bypass that policy. Optional external sensor channels still start at 14.
|
|
Historical samples retained from a previous carrier selection describe the old
|
|
samples, not current sensor availability.
|
|
|
|
Voltage history reserves native channel IDs 2..5 at boot, even while Auto is
|
|
pending or Basic is selected. This is schema allocation, not chip access or a
|
|
measurement. It lets later detection, charger input power or a manual mode
|
|
change supply valid samples without restarting or clearing unrelated history.
|
|
Inactive readings remain missing, and empty channels do not appear in populated
|
|
history results. Native and optional I2C voltage history use the existing
|
|
`get telemetry.volt.i2c <channel> [1-4]` reader: four days of 30-minute RAM samples.
|
|
|
|
Where telemetry history is included, `get solar history` points to the existing
|
|
`get telemetry.volt [1-7]` and `get telemetry.temp [1-7]` commands: 30-minute
|
|
samples, seven days in RAM. History starts filling after boot and resets at
|
|
reboot. Voltage trends can help assess a remote installation, but are not a
|
|
measurement of solar power, charge current or charge state. Radio/status and
|
|
history-transfer commands remain the existing role commands.
|
|
|
|
The selection is stored separately in an eight-byte, versioned checked record
|
|
at `/solar_board`, using atomic publication and full public readback. A corrupt,
|
|
unreadable or unconfirmed selection blocks native access and replay. Self ADC
|
|
and MCU readings remain available. An explicit successful `set solar.board`
|
|
recovers selection. With an unavailable filesystem, the selection cannot be
|
|
saved and native access remains blocked.
|
|
|
|
When auto verifies MPPT or a manual MPPT selection re-enables native access,
|
|
the firmware reloads any retained `/solar_power` charger overrides. Changing the
|
|
carrier does not erase those overrides, change RF/PA settings, modify battery
|
|
protection, or write charger defaults. The INA260 identity verifies the monitor;
|
|
LTC4162 chemistry and cell-count checks still independently guard charger writes.
|
|
|
|
Radio target and role selection remain separate from the power profile:
|
|
|
|
| Fitted module | Repeater | Room Server |
|
|
| --- | --- | --- |
|
|
| E22 M30S | `solarxiao_30S_repeater` | `solarxiao_30S_room_server_lora_ota` |
|
|
| E22 M33S | `solarxiao_33S_repeater` | `solarxiao_33S_room_server_lora_ota` |
|
|
|
|
All three power profiles work in these role builds. Room uses its existing
|
|
onboard-QSPI OTA target, identity and application layout, with the matching
|
|
board/storage-aware OTAFIX bootloader. The older plain `*_room_server` targets
|
|
remain separate compatibility/recovery recipes; this native interface is
|
|
qualified on the QSPI OTA Room targets. No legacy identity is remapped.
|
|
|
|
The
|
|
published Base Standard schematic specifies M30S; the pictured 2W Advanced
|
|
uses M33S. Charger detection cannot identify the PA variant or select its TX
|
|
power limits.
|
|
|
|
A remotely deployed node must first receive compatible firmware before these
|
|
commands can be used. Deployment still requires its installed target and
|
|
bootloader compatibility to be checked when it is reachable.
|
|
|
|
See the [Room Server and late-detection history validation](test-results/solarxiao_room_2026-10-21.md)
|
|
and [three-profile validation](test-results/solarxiao_basic_2026-10-21.md).
|
|
This adds no measurements beyond existing self voltage/MCU temperature and has
|
|
not been installed on the remote Advanced board.
|
|
|
|
## MPPT carrier commands
|
|
|
|
Start with:
|
|
|
|
```
|
|
get mppt
|
|
get mppt battery
|
|
get mppt power
|
|
get mppt alerts
|
|
get mppt saved
|
|
get mppt fields 0
|
|
```
|
|
|
|
`fields` returns three names per page with `rw`, `ro` or `locked`. Increment the
|
|
page to enumerate the register interface. `get mppt <field>` returns units and
|
|
the raw register. `get mppt raw 0x43` reads a documented register; arbitrary
|
|
register writes are not exposed. `nan` in a summary means unavailable, not zero.
|
|
|
|
## Identity and readings
|
|
|
|
The carrier bus uses SDA P0.09 and SCL P0.10. INA260 at `0x40` must match its TI
|
|
manufacturer and device IDs. Its signed current, voltage and power readings do
|
|
not require charger input power. The driver does not reset/configure INA260.
|
|
LTC4162 at `0x68` uses little-endian SMBus words. Access normally requires power
|
|
at SOLAR/VIN; USB alone can leave the charger unavailable.
|
|
|
|
`get mppt info` reports the chemistry/profile code, live cell count, last observed
|
|
nonzero cell count, MPPT, JEITA, charger state and telemetry validity. The actual
|
|
bench board identified as FST (chemistry code 6); this distinguishes it from
|
|
FAD, FFS, Li-ion and SLA variants. The ID does not uniquely identify the M suffix
|
|
or package/temperature grade. Cell count comes from hardware straps; zero means
|
|
unknown while the charger is inactive. Software cannot change chemistry/cells.
|
|
|
|
Readings cover battery/input/output voltage, signed battery/input current,
|
|
charger die and modeled NTC temperature, battery series resistance, charge/CV/
|
|
absorb timers, JEITA region, actual DAC settings, system/status bits and all three
|
|
alert banks. A retained ADC bank is not presented as live while telemetry is off.
|
|
Battery ADC voltage/resistance need a currently valid cell count. Questionable
|
|
resistance and an open/disconnected NTC return unavailable in the summaries.
|
|
|
|
## Settings on the 4S FST carrier
|
|
|
|
Use `set mppt <field> <value>`. Booleans accept `on` or `off` only.
|
|
|
|
| Fields | Behavior |
|
|
| --- | --- |
|
|
| `mppt.enabled` | Enable automatic solar maximum power tracking. |
|
|
| `charge.enabled` | Suspend/resume charging; does not disconnect the battery or system output. |
|
|
| `telemetry.force`, `telemetry.fast` | Force the charger ADC on, or use fast telemetry. These affect power consumption. |
|
|
| `input.limit_ma` | Input current limit; rounds down to the hardware step, never above the request; maximum request 3200 mA. |
|
|
| `input.minimum_mv` | Manual input-voltage floor; MPPT must be off. Rounds up in 140.625 mV steps, maximum request 35000 mV. |
|
|
| `jeita.enabled` | Select the fixed multi-region JEITA profile or basic temperature-qualified manual targets. |
|
|
| `charge.current_ma`, `charge.cell_mv` | Manual targets require JEITA off. Current rounds down in resistor-dependent steps, up to 3200 mA. This 4S board interface limits voltage requests to 3412.5..3600 mV/cell in 12.5 mV steps. |
|
|
| `thermal.start_c`, `thermal.end_c` | Die thermal regulation thresholds, -40..125 C; start must remain below end. |
|
|
| `termination.enabled`, `termination.current_ma` | C/x termination switch and nonnegative current threshold. |
|
|
| `termination.cv_seconds`, `termination.total_minutes` | 16-bit safety timers; zero disables the corresponding timer. |
|
|
| `alert.*` | Voltage/current/die/NTC/resistance thresholds and enabled alert masks; use field names/units from `fields`. |
|
|
|
|
FST locks the six JEITA thresholds, regional current/voltage values, recharge
|
|
threshold and absorb voltage/time. These remain readable. Manual target
|
|
registers are continuously overwritten by JEITA when JEITA is on; read actual
|
|
`dac.*` fields to see the active regulation targets. Basic temperature-qualified
|
|
charging still uses the fixed outer temperature limits when JEITA is off.
|
|
|
|
All configuration writes require a fresh FST identity and a live cell count of
|
|
4 or unknown. Other variants remain readable but cannot receive this board's
|
|
saved settings. Every setting uses a masked register update and verifies
|
|
readback before success. Unrelated bits are preserved; one-shot BSR is not
|
|
replayed by configuration writes. A failed write/save attempts to restore the
|
|
previous field and reports whether rollback was verified.
|
|
|
|
## Saving and actions
|
|
|
|
Successful settings save an explicit override in a versioned, CRC-protected
|
|
`/solar_power` record, using atomic file replacement plus public-file readback.
|
|
The board reapplies only saved overrides after restart or charger power loss,
|
|
with a five-second retry interval. It does not write default settings on first
|
|
boot. JEITA-owned targets are not repeatedly written while JEITA is enabled.
|
|
A failed/corrupt settings file blocks configuration saves and automatic replay.
|
|
|
|
- `mppt reload`: reload saved policy and retry applying it.
|
|
- `mppt forget`: remove saved register overrides; keep calibration and live chip settings.
|
|
- `mppt reset`: local USB only; reset saved policy/calibration to reference values,
|
|
including recovery from a corrupt record. Live charger registers are unchanged.
|
|
- `mppt bsr run`: request one battery-resistance measurement; not saved.
|
|
- `mppt ship arm` / `mppt ship disarm`: local USB only; not saved. Arming takes
|
|
effect when VIN drops below approximately 1 V and can remove system power.
|
|
- `mppt alerts clear limits|states|status <mask>`: clear selected latched alerts
|
|
using write-zero-to-clear semantics; unselected/new alerts are preserved.
|
|
|
|
These actions acknowledge the request, not completion of charging, resistance
|
|
measurement or entry into ship mode. Read the corresponding status afterward.
|
|
|
|
See the [bench acceptance report](test-results/solarxiao_power_2026-10-21.md)
|
|
for exact firmware identity, measured readouts and test limits.
|
|
|
|
## Conversion defaults and carrier revisions
|
|
|
|
The supplied [Standard schematic](https://github.com/wehooper4/Meshtastic-Hardware/blob/main/XaioSeries/SolarXaio/MPPT/Standard/Schematic_SolarXaio_MPPT_2025-10-23.pdf)
|
|
shows R5/RSNSI and R14/RSNSB at 10 milliohms, a 10 kohm NTC bias and a 10 kohm
|
|
NTC. It shows an L42M single-cell charger, so it does not independently confirm
|
|
component values on this 12 V FSTM revision. Defaults use those resistor values
|
|
and the LTC4162 reference thermistor beta of 3490 K. Readings identify the model
|
|
as `reference` until the corresponding calibration values are explicitly set.
|
|
|
|
Calibration settings, saved without changing hardware target registers:
|
|
|
|
```
|
|
get mppt cal.rsnsb_mohm
|
|
get mppt cal.rsnsi_mohm
|
|
get mppt cal.ntc_bias_ohm
|
|
get mppt cal.ntc_r25_ohm
|
|
get mppt cal.ntc_beta
|
|
```
|
|
|
|
Set these with the same `set mppt` syntax after confirming actual components.
|
|
Allowed sense resistance is 0.1..1000 milliohms, NTC/bias resistance 100..1000000
|
|
ohms, beta 1000..10000 K. The simple beta temperature model assumes an unpadded
|
|
NTC divider. It does not model series/parallel thermistor dilution networks.
|
|
Changing calibration changes units/conversions, not already saved register codes.
|
|
INA260 uses its integrated shunt and does not use these sense-resistor values.
|
|
|
|
## Telemetry channels
|
|
|
|
The following carrier channels apply to MPPT mode. Advanced mode reports the
|
|
existing self voltage/MCU temperature on channel 1 and omits native channels.
|
|
|
|
Carrier telemetry requires the environmental telemetry permission. Channel 1
|
|
remains the XIAO internal ADC; it is separate from the 4S carrier battery and its
|
|
existing startup/low-voltage policy is unchanged.
|
|
|
|
| Channel | Values |
|
|
| --- | --- |
|
|
| 2 | INA260 battery voltage, signed current, power |
|
|
| 3 | LTC4162 input voltage, signed current, computed nonnegative input power |
|
|
| 4 | Charger system output voltage |
|
|
| 5 | Charger battery ADC voltage and signed current |
|
|
| 6, 7 | Die temperature, modeled NTC temperature |
|
|
| 8, 9, 10 | Generic sensor integers: charger state, charge status, system bits |
|
|
| 11, 12, 13 | Generic sensor integers: limit, state and status alert masks |
|
|
| 14 onward | Optional environmental sensors, in discovery order |
|
|
|
|
Unavailable values are omitted. Voltage history reserves channels 2..5 and
|
|
marks unavailable samples invalid. The generic sensor scanner cannot claim
|
|
carrier addresses `0x40`/`0x68`; this prevents an INA219 driver from configuring
|
|
the INA260 and keeps carrier channels stable across profiles and power states.
|
|
No state-of-charge percentage or coulomb counting is inferred from voltage.
|
|
|
|
References: [SolarXaio hardware](https://github.com/wehooper4/Meshtastic-Hardware/tree/main/XaioSeries/SolarXaio),
|
|
[LTC4162-F Rev A](https://www.analog.com/media/en/technical-documentation/data-sheets/ltc4162-f.pdf),
|
|
[INA260](https://www.ti.com/lit/ds/symlink/ina260.pdf).
|