On battery with the Cap on, 79% of the gauge reads failed, in groups of
up to 110 s. The poll read 3 times in 11 s and then waited 20 s, so it
missed the good periods, and after 7 failed polls the gauge went away.
- After a failed read, the next read comes after 5.5 s, not 20 s.
- The last good reading stays for 10 minutes instead of 7 polls.
- A change of the charging flag waits for a second read that agrees,
because a garbled read said Charging while the pack discharged.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>