The charger cuts out at full, the pack settles back to 99, the charger
restarts - and the companion reports that flip every poll for as long
as the thing is plugged in. The gauge is pinned to the header's right
edge and the pulse takes whatever is left, so the fourth cell 100%
needed came off the sparkline and redrew the whole activity history at
a new scale, twice a minute, on a device sitting still.
A full pack reads `100` now, with no sign: three cells, exactly as the
`99%` it keeps flipping back to. It is the one reading whose `%` can
be inferred - a bare 100 beside a full block is a percentage without
being told - and the sign goes on doing its work at every charge that
could be mistaken for something else.
Only that pair is answered, deliberately. The other width change in
the range, 9 to 10, is a boundary a discharging pack crosses once and
never comes back over: one repaint, no jitter, nothing to fix.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>