Battery: use the standard BLE charging flag when a device exposes it
The companion protocol reports only a battery voltage, so charging is a voltage-trend inference. Some devices could instead expose the standard GATT Battery Service (0x180F) whose Battery Level Status characteristic (0x2BED, Battery Service 1.1) carries a real, firmware-reported charging flag. Dumping the GATT table shows no current MeshCore build implements it — the BLE profile is just the Nordic UART pipe plus DFU — but wire it up now so it lights up automatically the day one does. get_hw_charging() reads 0x2BED best-effort over BLE (reaching the bleak client the forced-teardown path already uses) and prefers its flag; any failure — service absent, read refused, short value, non-BLE transport — is a quiet None, so the poller falls back to the inference and every current device behaves exactly as before. Verified against a live device: the read resolves and returns a clean, steady None. The 0x2BED bitfield decode is a pure function unit-tested against the spec's Charge State enum so the parse is correct ahead of any hardware that populates it. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
This commit is contained in:
1 parent
e73cea9f42
commit
6aecb58e59
3 files changed
+159
-8
No files matched your search
+62
-3
@@ -8,8 +8,10 @@ charging inference are all assertable without a device or a terminal.
|
||||
from __future__ import annotations
|
||||
|
||||
import asyncio
|
||||
import time
|
||||
from types import SimpleNamespace
|
||||
|
||||
from meshterm.core.connection import charging_from_battery_level_status
|
||||
from meshterm.services.battery_service import (
|
||||
_BATTERY_PRESENT_FLOOR_MV,
|
||||
POLL_S,
|
||||
@@ -85,15 +87,22 @@ def test_battery_cell_charging_sweeps_bottom_to_full_holding_the_percent() -> No
|
||||
# --- the poller ---------------------------------------------------------------------------
|
||||
|
||||
|
||||
def _service(levels) -> BatteryService:
|
||||
"""A ``BatteryService`` over a fake context whose device answers ``levels`` in turn."""
|
||||
def _service(levels, hw_charging=None) -> BatteryService:
|
||||
"""A ``BatteryService`` over a fake context whose device answers ``levels`` in turn.
|
||||
|
||||
``hw_charging`` is what the device's firmware charging flag reports each poll — ``None``
|
||||
(the default, and every real MeshCore device) means "no flag", so the poller infers.
|
||||
"""
|
||||
seq = list(levels)
|
||||
|
||||
async def get_battery() -> dict:
|
||||
return {"level": seq.pop(0)} if seq else {}
|
||||
|
||||
async def get_hw_charging():
|
||||
return hw_charging
|
||||
|
||||
async def device() -> SimpleNamespace:
|
||||
return SimpleNamespace(get_battery=get_battery)
|
||||
return SimpleNamespace(get_battery=get_battery, get_hw_charging=get_hw_charging)
|
||||
|
||||
ctx = SimpleNamespace(
|
||||
is_connected=True,
|
||||
@@ -175,3 +184,53 @@ def test_battery_poller_charging_ignores_load_sag_and_flat_or_falling_packs() ->
|
||||
svc._history.clear()
|
||||
svc._history.extend(_history_of(now, [3800, 3900]))
|
||||
assert svc._charging(now) is False
|
||||
|
||||
|
||||
# --- the standard BLE charging flag (GATT Battery Level Status, 0x2BED) --------------------
|
||||
|
||||
|
||||
def _level_status(charge_state: int, *, flags: int = 0, extra: bytes = b"") -> bytes:
|
||||
"""A Battery Level Status value: flags byte, the Power State word, then optional tail."""
|
||||
power_state = (charge_state & 0b11) << 5
|
||||
return bytes([flags]) + power_state.to_bytes(2, "little") + extra
|
||||
|
||||
|
||||
def test_charging_flag_decodes_the_charge_state_field() -> None:
|
||||
"""The 2-bit Charge State enum maps to charging / not / unknown per the GSS."""
|
||||
assert charging_from_battery_level_status(_level_status(1)) is True # charging
|
||||
assert charging_from_battery_level_status(_level_status(2)) is False # discharging (active)
|
||||
assert charging_from_battery_level_status(_level_status(3)) is False # discharging (inactive)
|
||||
assert charging_from_battery_level_status(_level_status(0)) is None # unknown → infer
|
||||
|
||||
|
||||
def test_charging_flag_reads_only_the_power_state_word() -> None:
|
||||
"""Other Power State bits and the optional identifier/level tail don't sway the verdict."""
|
||||
# Battery present + wired external power + charging, with identifier & level bytes trailing.
|
||||
value = _level_status(1, flags=0b011, extra=b"\xab\xcd\x50")
|
||||
assert charging_from_battery_level_status(value) is True
|
||||
# A short value (no room for the Power State word) is unknown, never a guess.
|
||||
assert charging_from_battery_level_status(b"\x00") is None
|
||||
assert charging_from_battery_level_status(b"") is None
|
||||
|
||||
|
||||
def test_battery_poller_prefers_the_hardware_charging_flag_over_inference() -> None:
|
||||
"""A firmware charging flag wins over the voltage-trend guess, in both directions."""
|
||||
now = time.monotonic()
|
||||
rising = [3700, 3712, 3724, 3736, 3748, 3760, 3772, 3784]
|
||||
|
||||
# Baseline: with no hardware flag the rising trend is *inferred* as charging.
|
||||
svc = _service([3900], hw_charging=None)
|
||||
svc._history.extend(_history_of(now, rising))
|
||||
asyncio.run(svc._poll())
|
||||
assert svc.reading().charging is True
|
||||
|
||||
# Same rising trend, but the hardware reports NOT charging → the flag overrides the guess.
|
||||
svc = _service([3900], hw_charging=False)
|
||||
svc._history.extend(_history_of(now, rising))
|
||||
asyncio.run(svc._poll())
|
||||
assert svc.reading().charging is False
|
||||
|
||||
# And a hardware "charging" wins with no trend at all, where inference would say not.
|
||||
svc = _service([3900], hw_charging=True)
|
||||
asyncio.run(svc._poll())
|
||||
assert svc.reading().charging is True
|
||||
Reference in new issue