Node hues share one OKLab lightness, so every name and chip reads alike

The spectrum was an HSV wheel at one saturation and value, which is not
one lightness to the eye: blue names sat at OKLab L 0.55 and yellow at
0.93. A chip's fill is its label at CHIP_LIGHTNESS of that lightness, so
chip contrast followed the label, from APCA Lc 19 on blue to 64 on
yellow.

Each byte now keeps its HSV hue angle and chroma at OKLab L 0.72, with
the chroma fitted where the gamut cannot hold it. JP chose 0.72 on a
ladder of wheels from 0.70 to 0.85. Every name reads equally light and
every chip lands at Lc 34 to 41.

The 256 colours are written out as _NODE_SPECTRUM, because computing
them costs about 14 ms here and _IDENTITY_STYLES needs all of them at
import, which would slow every start on the handhelds. A test holds the
table to _spectrum_hex, and checks one lightness, 256 distinct hues, no
console-slot collision, and that each hue angle is kept.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
This commit is contained in:
Jean-Pierre MartineauandClaude Opus 5.5 committed 2026-10-29 01:05:13 -04:00
1 parent f296413a5e
commit 598e53b488
5 files changed
+147 -18

No files matched your search

+5 -2
View File
@@ -35,7 +35,7 @@ def test_the_wheel_is_not_uniform_to_the_eye() -> None:
"""One hue step is small in green and large in cyan. This is why the module exists."""
green = oklab.distance(_fill("4c"), _fill("5c"))
cyan = oklab.distance(_fill("80"), _fill("90"))
assert green < 0.03 < 0.15 < cyan
assert green < 0.03 < 0.08 < cyan # also on the spectrum of one lightness (2026-10-29)
def test_shaded_moves_lightness_alone_away_from_the_nearer_end() -> None:
@@ -66,10 +66,13 @@ def test_fitted_lowers_chroma_alone_and_keeps_near_hues_apart() -> None:
A colour in the gamut is returned unchanged. The clip in ``to_hex`` made two dark
greens near ``0x50`` almost one colour. After the fit, they are clearly two colours.
The two greens are ``0x4c`` and ``0x5c`` of the HSV wheel that the spectrum used before
2026-10-29. The spectrum of one lightness has less chroma in the greens, so its own
greens leave the gamut less when they are darker.
"""
inside = oklab.from_hex(_fill("80"))
assert oklab.fitted(inside) == inside
darker = [oklab.from_hex(_fill(key)) for key in ("4c", "5c")]
darker = [oklab.from_hex(green) for green in ("#77f255", "#55f26d")]
outside = [(lab[0] * 0.6, lab[1], lab[2]) for lab in darker]
fits = [oklab.fitted(lab) for lab in outside]
clipped = oklab.distance(*(oklab.to_hex(lab) for lab in outside))