Files
MeshCore/docs/lora_ota_automation.md
T

17 KiB

Scripted LoRa OTA from start to finish

tools/lora_ota/lora_ota.sh and tools/lora_ota/lora_ota.ps1 automate a MeshCore LoRa firmware update from a release .zip or ready .mota. They identify the destination, validate the hardware and running firmware, prepare the right container, move the participating nodes to a temporary radio channel, serve and monitor the download, request installation, restore the controller, and check the rebooted node.

The script cannot install the destination's first OTA-capable firmware or its nRF52 bootloader. Do those one-time jobs over USB before using LoRa OTA.

Required topology

The reliable serial topology uses two local radios:

                                      authenticated admin commands
computer -- MeshCore binary API --> controller Companion -------------------+
   |                                                                         |
   +-- raw text CLI + mOTA seeder --> OTA source ---- LoRa OTA blocks ----> target
                                                        |                    ^
                                                        +-- relay(s) --------+
  • Controller: a Companion connected through serial, TCP, or BLE. The script uses meshcli to send remote admin commands to the target and changes the controller's live radio parameters during the transfer. A serial Companion stays in its normal Binary USB mode at 115200 baud.
  • OTA source: a separate OTA-enabled repeater or FULL node whose USB port is a raw text CLI and supports ota folder on. motatool uses that same link for its binary seeder frames after enabling the folder.
  • Target: an OTA-enabled ESP32 or nRF52 node present in the controller's contact list. Its admin password is required.
  • Relays: optional. They do not need to install OTA themselves, but every relay on the path must be running current firmware and have an overlapping TempRadio window.

One serial port cannot serve both controller roles: meshcli must keep reopening the controller while motatool owns the source port. The script rejects an attempt to use the same port for both.

The Companion USB ASCII switch (+++MESHCORE-TERM-START) is an interactive chat terminal, not the raw repeater/FULL management CLI expected by motatool. It does not make a Companion's serial port an OTA seeder. For a WiFi seeder, use a FULL/repeater source's port 5001 plus its raw USB CLI, as shown below.

Destination requirements

Destination Package installed One-time prerequisite Raw ZIP handling
ESP32 Full application image OTA-enabled image with an A/B partition table Builds a full mOTA from the matching non-merged application .bin
nRF52, internal flash In-place delta Exact-board OTAFIX bootloader with mOTA apply support Requires --base with the exact image currently running
MeshTower V2 nRF52, microSD Full image or in-place delta SD-aware exact-board OTAFIX bootloader and compatible card Builds a full mOTA; adding --base requests a delta

The firmware inside a raw ZIP must have a valid MeshCore EndF trailer. An ESP32 merged/factory image is not an application image and is rejected. A generic vendor DFU ZIP may also be unusable if it does not contain the raw EndF-bearing .hex or .bin.

For an internal-flash nRF52, the exact base image is irreducible information. The node reports its eight-byte body hash, but that hash cannot reconstruct the firmware bytes needed to create a delta. Keep the .pio/build/ENV/firmware.hex that was actually flashed. A matching filename or version alone is not enough.

1. Install the host tools

Install Python 3.10 or newer, Rust, Git, the official meshcore-cli, and the official motatool.

On Bash:

python3 -m pip install --user pipx
python3 -m pipx ensurepath
pipx install meshcore-cli

git clone https://github.com/vk496/motatool.git
cargo install --path ./motatool

meshcli -v
motatool --version

On PowerShell:

py -m pip install --user pipx
py -m pipx ensurepath
pipx install meshcore-cli

git clone https://github.com/vk496/motatool.git
cargo install --path .\motatool

meshcli -v
motatool --version

Restart the shell if pipx or Cargo reports that it changed PATH.

List serial devices:

meshcli -l

The examples below assume /dev/ttyACM0 is the controller and /dev/ttyACM1 is the OTA source. On Windows they might be COM7 and COM8. Close picocom, a serial monitor, the phone app, and any other program holding either link.

Test the controller's binary API:

meshcli -s /dev/ttyACM0 -b 115200 ver

Test the source's raw text CLI and OTA support:

meshcli -r -s /dev/ttyACM1 -b 115200 "ota status"

The second command must print an OTA | ... target:XXXXXXXX status. The automation repeats this preflight and stops before changing any radios if the source is the wrong build or interface.

Changing a terminal to 57600 baud does not select ASCII mode. USB Companion builds and the normal raw management CLI use 115200 unless a particular build was explicitly configured otherwise.

3. Check the destination once

The destination must be in the controller's contacts and remotely reachable on the normal channel. The script runs these authenticated checks itself:

ota status
ota self
ota stats

For nRF52, ota self must report bootloader: apply OK or bootloader: SD apply OK. The script also checks the reported bootloader ABI and codec mask against the selected package.

The default TempRadio tuple is:

909.950,250,7,5,120

The 250 kHz bandwidth, SF7, and CR5 combination is supported by every current sub-GHz radio family used in USB Companion builds, including older SX127x controllers (which do not support SF5). The frequency is only a North American example: choose a legal frequency supported by every participating radio and appropriate to your location. Pass the complete replacement tuple with --temp-radio.

4. Run an ESP32 update

The ZIP can contain a compatible ready .mota or the exact board-and-role non-merged application .bin:

export MESHCORE_ADMIN_PASSWORD='target-admin-password'

./tools/lora_ota/lora_ota.sh ./release.zip "Roof ESP32" \
  --controller-serial /dev/ttyACM0 \
  --source-serial /dev/ttyACM1

The script shows the detected target, hardware, running hash, chosen package, version, manifest ID, and action before asking for confirmation. For an unattended job, add --yes:

./tools/lora_ota/lora_ota.sh ./release.mota "Roof ESP32" \
  --controller-serial /dev/ttyACM0 \
  --source-serial /dev/ttyACM1 \
  --yes

PowerShell equivalents:

$env:MESHCORE_ADMIN_PASSWORD = 'target-admin-password'

& .\tools\lora_ota\lora_ota.ps1 '.\release.zip' 'Roof ESP32' `
  --controller-serial COM7 `
  --source-serial COM8

& .\tools\lora_ota\lora_ota.ps1 '.\release.mota' 'Roof ESP32' `
  --controller-serial COM7 `
  --source-serial COM8 `
  --yes

Prefer the environment variable or the interactive password prompt. Passing --password works, but the wrapper's own command line may be visible to other local processes. The runner keeps the password out of child meshcli command lines and removes its protected temporary command file after each call.

5. Run an internal-flash nRF52 update

If the input ZIP already contains a compatible in-place delta .mota, no base argument is needed: its embedded base hash is compared with the live node. If the ZIP contains raw new firmware, supply the exact running image:

./tools/lora_ota/lora_ota.sh ./nrf52-new-release.zip "Hill nRF52" \
  --base ./firmware-that-is-running.hex \
  --controller-serial /dev/ttyACM0 \
  --source-serial /dev/ttyACM1
& .\tools\lora_ota\lora_ota.ps1 '.\nrf52-new-release.zip' 'Hill nRF52' `
  --base '.\firmware-that-is-running.hex' `
  --controller-serial COM7 `
  --source-serial COM8

Before building the delta, the runner proves that the base's target ID, hardware identity, firmware version when available, and EndF body hash match the live destination. It then asks motatool for codec 2, the nRF52 in-place format. The normal workspace is 0x98000.

For the SD-backed MeshTower V2 target, a raw ZIP becomes a full image without --base. Supplying an exact base requests a smaller in-place delta and automatically selects its 0xC7000 workspace. An explicit --inplace-memory overrides the automatic value.

6. Add intermediate relays

List relays from farthest to nearest so each command is sent before its route moves to TempRadio. A bare relay name uses the destination password; use NAME=PASSWORD when it differs:

./tools/lora_ota/lora_ota.sh ./release.mota "Remote Target" \
  --controller-serial /dev/ttyACM0 \
  --source-serial /dev/ttyACM1 \
  --relay "Far Relay=far-password" \
  --relay "Near Relay=near-password"

PowerShell uses the same arguments:

& .\tools\lora_ota\lora_ota.ps1 '.\release.mota' 'Remote Target' `
  --controller-serial COM7 `
  --source-serial COM8 `
  --relay 'Far Relay=far-password' `
  --relay 'Near Relay=near-password'

Other connection choices

The controller can use any one of:

--controller-serial PORT
--controller-tcp HOST[:PORT]       # default port 5000
--controller-ble ADDRESS_OR_NAME

An ESP32 FULL/repeater source can serve over its dedicated WiFi seeder port while its raw USB CLI is used to start TempRadio:

./tools/lora_ota/lora_ota.sh ./release.mota "Remote Target" \
  --controller-serial /dev/ttyACM0 \
  --source-tcp 192.168.1.50:5001 \
  --source-cli-serial /dev/ttyACM1

If the source is already on the exact TempRadio tuple through a scheduled or manual operation, --source-already-temp lets a TCP source run without a raw CLI link. The script cannot verify, extend, or shorten that source window, so leave a comfortable time margin.

Use --controller-baud or --source-baud only for a build whose corresponding interface is genuinely configured to another speed.

Package selection and safety gates

For a ZIP, the runner first examines every .mota without extracting paths. It keeps only packages matching the live target, hardware, base, platform, codec, and bootloader capabilities. It chooses the newest compatible version and prefers a delta over a full image at the same version. If equally suitable files differ, select one explicitly:

--zip-member path/inside/archive/update.mota

If no ready mOTA is usable, it searches .bin and .hex members for a valid, matching EndF, then builds the platform-appropriate container. Every result is structurally checked by the runner and independently passed through motatool verify before any radio changes. Direct firmware and mOTA inputs, as well as individual ZIP members, are rejected above 64 MiB before being loaded.

Useful controls:

  • --public-key signer.key.pub requires a particular Ed25519 signer during verification.
  • --sign-key signer.key signs a newly built container.
  • --no-install downloads and verifies the image but leaves it staged. By default the runner then schedules the target, relays, and a script-configured source back to their normal radios. Combining it with --leave-controller-radio deliberately preserves the TempRadio topology.
  • --allow-non-upgrade deliberately permits the same or an older version.
  • --replace-active-download deliberately discards a different update already downloading or staged on the target. Without it, that update is preserved.
  • --work-dir PATH chooses a new, non-existent work directory.
  • --meshcli PATH and --motatool PATH select binaries not on PATH.

For offline package preparation only:

./tools/lora_ota/lora_ota.sh ./release.zip offline \
  --prepare-only \
  --platform nrf52 \
  --target-id 1234ABCD \
  --target-base-hash 0011223344556677 \
  --target-hw Heltec_T114 \
  --base ./firmware-that-is-running.hex

Live operation is safer because the script obtains these values directly from the destination.

What happens during a run

  1. Validate the input paths and host tools, then prove the source is an OTA-enabled raw CLI.
  2. Authenticate to the target and query its target ID, hardware, running body hash, version, and nRF52 bootloader capabilities.
  3. Select or build one compatible mOTA and verify all block hashes, Merkle root, full-image hash where applicable, identity fields, signature, codec, base, and the firmware's 1024-byte maximum block size.
  4. Save the controller's normal radio tuple and show the confirmation prompt.
  5. Start TempRadio on the target, then far-to-near relays, then the source; finally switch the controller to the same tuple and read it back. The runner rejects a TempRadio window that cannot cover setup, seeder startup, discovery, the transfer timeout, final polling, and install checks.
  6. Start motatool serve, discover the exact eight-hex manifest ID, request ota pull <id> flash, and poll until that same ID reports ready. A seeder process exit stops the run immediately. For --no-install, schedule all script-controlled nodes back to their normal radios before restoring the controller, unless --leave-controller-radio was requested.
  7. Recheck that exact ID, give the target a short final TempRadio safety window, and request ota install. Then shorten each relay's TempRadio window so the normal multi-hop route returns, stop the seeder, shorten the source window, restore the controller, wait for reboot, and require the new running identity and exact package version. A source supplied with --source-already-temp is never modified. --leave-controller-radio moves the controller back to TempRadio only after this normal-channel verification.

Remote replies are matched only after queued messages have been drained and only when they come from the intended contact and fit the command. A ready status for another manifest ID is an error, never permission to install it.

Transmission loss and retries

Read-only and replay-safe transmissions retry up to three times. Three retries or 90 seconds, whichever comes first, opens a 10-second stop-or-continue prompt. Continue is the default on timeout, Enter, and unattended input, so a temporary outage does not silently abandon a resumable transfer. Enter s or stop to end the run; Ctrl-C also remains immediate.

Commands that change OTA state are reconciled before replay:

  • After a lost ota pull reply, ota status must show the requested manifest ID before the runner treats the pull as started. Otherwise the safe retry policy applies.
  • A lost ota install reply is not blindly resent. After a short wait, it is sent again only if the target replies that the same manifest is still ready. If the target has stopped replying because it may be rebooting, the runner restores the normal path and lets post-reboot identity resolve the outcome. The target's final three-minute safety window also returns a non-rebooting target to the normal channel promptly.

Retries and operator-selected continuation can outlast the original TempRadio budget. If a bounded window expires, rerun the same package after the nodes return to their normal channel; the manifest-ID check resumes its partial download without replacing it.

The working directory is retained and printed at exit. It contains the exact served mOTA, motatool-serve.log, extracted build inputs when needed, and controller-radio.txt. It contains no saved admin password.

Interruption and recovery

Ctrl-C stops the seeder, detaches its serial folder, makes one best-effort request to shorten a source TempRadio window started by the script, and attempts to restore the controller. The target and relays remain on TempRadio only until their bounded windows end; rebooting also restores their saved radio settings. A partial download remains safe. Once the target is reachable again (after its TempRadio window ends, or after putting the controller back on that tuple), rerunning the same package recognizes its manifest ID and resumes the existing session instead of clearing it.

A hard process kill or host power loss cannot run cleanup. Recover a serial controller using the tuple saved in the printed work directory:

radio=$(tr -d '\r\n' < ./meshcore-lora-ota-20260807-123456-1234/controller-radio.txt)
meshcli -s /dev/ttyACM0 set radio "$radio"
$radio = (Get-Content '.\meshcore-lora-ota-...\controller-radio.txt' -Raw).Trim()
meshcli -s COM7 set radio $radio

If you stop during final confirmation, reconnect on the node's normal channel and run ota self and ver. A completed run returns success only when ota self reports a valid new body hash and ver exactly matches the package; an unverified install returns status 2. Do not immediately replace a staged image: the default active-download guard preserves it until you explicitly use --replace-active-download or run ota cancel.

Exit status is 0 for success, 2 for a validation or operational error, and 130 for Ctrl-C.