9.3 KiB
View this page on MeshCore Docs.
Telemetry decoder
The decoder runs on the documentation website. GitHub's Markdown preview shows the instructions but cannot run the decoder's buttons or JavaScript.
Paste raw hexadecimal packet data copied from the Let's Mesh packet analyzer to decode a repeater's temperature, battery-voltage, external I2C-voltage, or radio noise-floor snapshot. The decoder also accepts the payload hex without its MeshCore packet header and the Base64 pages returned by repeater or room-server CLI commands. Decoding happens entirely in this browser; pasted data is not uploaded or sent anywhere.
The Source ID in a raw-packet result is the first eight bytes of the sending repeater's public key. Match that 16-character hex value against the public-key prefix recorded for your repeaters. It comes from the telemetry payload itself, so it is available even when only the payload was copied.
Send raw telemetry packets
From an administrator CLI session, first configure a direct route to the MQTT
observer that will receive and upload the raw packets. Use direct when the
observer is a zero-hop neighbor:
set data.tx path direct
send telemetry.tx now
For a routed observer, provide its comma-separated hop hashes instead:
set data.tx path A1B2,C3D4
send telemetry.tx now
The shared route does not enable telemetry. Automatic telemetry is off on a fresh install; to explicitly keep the route manual-only before sending:
set telemetry.tx schedule off
send telemetry.tx now
The send telemetry.tx now command queues one TTB1 temperature packet, one
TVB1 battery-voltage packet, and IVB1 chunks for every connected I2C voltage
channel. TTB1 and TVB1 carry up to 165 samples. Each IVB1 carries 64, so a
full 192-point/four-day channel takes three packets. Channels whose retained
history is entirely zero are treated as disconnected and are not sent. The
command requires at least one collected base sample and works even when the
automatic schedule is off.
It also queues a N1B1 noise-floor packet once the main radio has completed a
15-minute history bucket. With radio2 enabled, it queues a separate N2B1
packet for that profile once it has a completed bucket. Each holds the latest
255 positions: up to 63 hours 45 minutes at 15-minute resolution. A position
can be Missing; failed measurements do not silently shorten the timeline.
The existing automatic transmission cadence is unchanged. Recording a new
noise-floor position every 15 minutes does not transmit a packet every 15 minutes.
Schedule changes are saved transactionally; a failed write does not truncate
the previous preferences. A legacy route must be successfully migrated into
data.tx before its schedule can run. Corrupt, unreadable, or ambiguously
committed preferences stop automatic and pending sends. get telemetry.tx
shows fault=prefs, and manual sends return an error instead of acknowledging
work that cannot run. Such a storage fault must be repaired before settings
can be changed; the firmware does not overwrite an unmigrated legacy file.
Decode a packet
If you are reading this on GitHub, open the working decoder on the documentation website to paste a packet, load an example, or download CSV.
Enable JavaScript on the documentation website to use the decoder.
Analyzer hex examples
The buttons load synthetic, protocol-valid zero-hop RAW_CUSTOM packets. A real snapshot can contain many more samples. Routed packets also contain path bytes before the telemetry payload magic; the decoder finds and validates the payload automatically.
Temperature
3E00545442311122334455667788800092651E0008000102354A4E5082
Battery voltage
3E00545642311122334455667788800092651E000800010264C8FEFFDC
External I2C voltage
3E00495642311122334455667788800092651E00020800000004019026927109C427107FFF
Radio1 noise floor
3E004E3142311122334455667788800092650F00080044CB77DF
All four examples identify the source as 1122334455667788.
CLI history pages
The same page continues to decode the padded Base64 returned by these administrator commands:
| Data | Newest page | Older-page example | Samples per page |
|---|---|---|---|
| MCU temperature | get telemetry.temp |
get telemetry.temp 2 |
48 (24 hours) |
| Battery voltage | get telemetry.volt |
get telemetry.volt 3 |
48 (24 hours) |
| I2C voltage | get telemetry.volt.i2c 2 |
get telemetry.volt.i2c 2 4 |
48 (24 hours) |
| GPS position | get telemetry.gps |
get telemetry.gps 2 |
24 (12 hours) |
| Main-radio noise floor | get telemetry.noise |
get telemetry.noise 2 |
Up to 176 (44 hours) |
| Radio2 noise floor | get telemetry.noise2 |
get telemetry.noise2 2 |
Up to 176 (44 hours) |
Paste either the complete reply beginning with > or Base64 alone. For
noise replies, the optional two-character CLI correlation prefix is accepted
too (01|Base64 or 01|> Base64). For example:
get telemetry.volt 1
> EkDUcWoeMAAB5+bl5eTj4uLh4ODf3t7d3Nvb2tnZ2NfX1tXU1NPS0tHQ0M/Ozc3My8vKycnI/w==
Run get telemetry.volt.i2c without a channel first to list connected
channels. For each channel, collect pages 1 through 4. Paste all four reply
lines into the decoder at once; it merges their timestamps into one 192-point,
four-day table and downloads them as one CSV. The same merging works for the
three IVB1 analyzer packets from a full channel. Inputs must have the same
telemetry type, source, LPP channel, radio profile, and sample interval.
Noise history retains eight days (768 quarter-hour positions) per profile in
RAM and resets on reboot. Page 1 is newest; up to five pages are available
as history fills. Paste the replies for one radio together to merge them.
Main-radio and radio2 pages remain separate. A full noise CLI page is 117
decoded bytes or 156 Base64 characters, fitting the current CLI reply buffer
over USB and administrator LoRa CLI. Radio2 history is read with
get telemetry.noise2, including when it is not being transmitted.
An INA3221 exposes its three enabled hardware inputs as three consecutive LPP
channels. When it is the only external sensor these are normally 2, 3, and
4, in hardware-input order. Other sensors can shift the numbers, so copy the
IDs reported by get telemetry.volt.i2c rather than assuming them.
Reading the table
- Timestamps default to UTC. Select Show browser-local time to convert them for display and CSV export.
TTB1means a raw temperature snapshot,TVB1a raw battery-voltage snapshot, andIVB1a packed external I2C-voltage chunk. The input summary also reports the MeshCore route and path-hop count when a complete packet was pasted.- Temperature preserves exact whole degrees from
-50 Cthrough+77 C, plus missing, below-range, and above-range states. - Voltage preserves hundredths of a volt from
1.88 Vthrough4.40 V, plus missing and out-of-range states. - External I2C voltage uses a 15-bit code at
0.02 Vresolution. Code0is missing/disconnected; codes1through32767cover0.02 Vthrough655.34 V. The LPP channel remains part of every page and raw chunk so multiple monitor inputs cannot be mixed accidentally. N1B1is main-radio noise history;N2B1is radio2 history. The chart and table use dBm. Codes0,1, and2mean-120,-119, and-118 dBm; codes3through29continue in 2 dB steps through-64 dBm. Code30is MAX, displayed as>-64 dBm, and code31is Missing. CSV uses separateradio_profile,status, andnoise_floor_dbmcolumns. MAX and Missing have an empty numeric field and leave gaps in the chart.- GPS positions are reconstructed from signed 10-meter differentials. A zero differential after the page origin is inherently ambiguous: it can represent an unchanged fix, movement below the encoded resolution, or no fix. The table labels those rows rather than inventing a coordinate.
- A GPS clipping warning means at least one movement exceeded the differential range, so positions after that point can be less accurate.
Each noise position combines three fresh noise-floor estimates collected
roughly five minutes apart within its UTC-aligned 15-minute bucket. If any
estimate is -100 dBm or lower, the minimum wins, including a bucket containing
both low and high values. Otherwise, if any estimate is -80 dBm or higher,
the maximum wins. Otherwise the three estimates are averaged. Minimums round
downward, maximums upward, and averages to the nearest encodable value. Values
below -120 dBm clamp to -120 dBm; values above -64 dBm become MAX.
Fewer than three fresh, valid estimates produce Missing. These are idle RSSI
noise estimates, not received-packet RSSI measurements.
GPS history remains available through the administrator CLI, but telemetry.tx
never puts GPS in RAW_CUSTOM packets. Location data therefore must come from a
CLI Base64 page rather than analyzer hex.
For the byte-level layouts, see Read repeater telemetry history.