Add meter-reference calibration with saved ADC corrections, checked persistence and rollback. Preserve existing board coefficients and nRF52 voltage policy, and merge the Mini Repeater feature gates. Validation: 69 focused tests, hosted documentation checks, and four firmware builds passed. Mini Repeater retains calibration and its existing filesystem with 376 flash bytes free; earlier Mini Sensor size failures remain documented.
42 lines
1.1 KiB
C++
42 lines
1.1 KiB
C++
#include "HeltecE290Board.h"
|
|
#include <helpers/ESP32GpioHold.h>
|
|
|
|
void HeltecE290Board::begin() {
|
|
ESP32Board::begin();
|
|
|
|
pinMode(PIN_ADC_CTRL, OUTPUT);
|
|
digitalWrite(PIN_ADC_CTRL, LOW); // Initially inactive
|
|
|
|
periph_power.begin();
|
|
|
|
esp_reset_reason_t reason = esp_reset_reason();
|
|
if (reason == ESP_RST_DEEPSLEEP) {
|
|
long wakeup_source = esp_sleep_get_ext1_wakeup_status();
|
|
if (wakeup_source & (1 << P_LORA_DIO_1)) { // received a LoRa packet (while in deep sleep)
|
|
startup_reason = BD_STARTUP_RX_PACKET;
|
|
}
|
|
|
|
mesh::esp32::releaseRtcGpioIfSupported((gpio_num_t)P_LORA_NSS);
|
|
mesh::esp32::deinitRtcGpioIfSupported((gpio_num_t)P_LORA_DIO_1);
|
|
}
|
|
}
|
|
|
|
uint16_t HeltecE290Board::getBattMilliVolts() {
|
|
analogReadResolution(10);
|
|
digitalWrite(PIN_ADC_CTRL, HIGH);
|
|
|
|
uint32_t raw = 0;
|
|
for (int i = 0; i < 8; i++) {
|
|
raw += analogRead(PIN_VBAT_READ);
|
|
}
|
|
raw = raw / 8;
|
|
|
|
digitalWrite(PIN_ADC_CTRL, LOW);
|
|
|
|
return calibrateBatteryMillivolts((5.42 * (3.3 / 1024.0) * raw) * 1000);
|
|
}
|
|
|
|
const char* HeltecE290Board::getManufacturerName() const {
|
|
return "Heltec E290";
|
|
}
|