# ESP-NOW bridge: simple setup Use two ESP32 LoRa boards to join two MeshCore networks with different radio settings. Each board repeats on its own LoRa network, and the boards exchange packets directly over 2.4 GHz ESP-NOW. No router, internet connection, or manual peer pairing is needed. ```text LoRa network A <--> Repeater A <-- ESP-NOW --> Repeater B <--> LoRa network B ``` ## 1. Choose the firmware Install the exact board's **Full repeater** image on each board. ESP-NOW is included as a runtime transport on supported ESP32 Full repeaters. Newly combined ordinary repeaters leave it off until explicitly enabled; that choice is saved across reboot. Boards with measured capacity exceptions keep separate `_repeater_bridge_espnow` images. Historical dedicated target names remain available for direct builds with their original bridge-on defaults. Full Companion is a different role. See the [firmware picker guide](firmware_picker.md). Open each board's [USB console](https://flasher.meshcore.io/console) at 115200 baud and run: ```text get bridge.type ``` The answer can be `espnow`, `mqtt+espnow`, `rs232+espnow`, or `mqtt+rs232+espnow`, depending on the image. Confirm the independent ESP-NOW control is present with `get espnow.enabled` and `get espnow.running`. The `espnow` commands select this transport without changing another bridge in a combined image. ## 2. Set each board's LoRa network Configure one board at a time over USB. Replace the placeholders below with the radio settings used by the network on that board's side. Use `Bridge-A` for the first board and `Bridge-B` for the second, or choose your own names. ```text set espnow.enabled off set name Bridge-A set radio ,,, reboot ``` Do not type the angle-bracket placeholders literally. | Radio option | Meaning | | --- | --- | | `freq` | LoRa frequency in MHz. Match the local network on this side. | | `bw` | LoRa bandwidth in kHz. Match that network's bandwidth. | | `sf` | Spreading factor, 5-12. Match that network's setting. | | `cr` | Coding-rate value, 5-8. Match that network's setting. | | `name` | A label to tell the two repeaters apart. It does not pair them. | **`set radio` requires a reboot to apply.** After reconnecting, `get radio` shows the saved settings. Use permanent radio settings for this setup; `tempradio` sessions expire. ## 3. Configure the ESP-NOW link on both boards Run this block on **both** boards. Replace `YourSharedKey` with the same case-sensitive secret on each board, using 1-15 characters. Channel `6` is an example; both boards must use the same channel. ```text set espnow.enabled off set bridge.channel 6 set bridge.format wrapped set bridge.secret YourSharedKey set bridge.source tx set bridge.delay 500 set repeat on set espnow.enabled on ``` These settings are saved across reboot. Bridge changes apply immediately; changing an enabled bridge's channel, format, or secret restarts the bridge. Stopping it first lets you finish configuring both sides before connecting them. ## What each bridge option does | Option | Choices and purpose | | --- | --- | | `espnow.enabled` | `on` starts ESP-NOW; `off` stops it and keeps its saved settings. Independent of MQTT or RS-232. | | `rs232.enabled` | On combined UART images, starts or stops RS-232 independently of MQTT and ESP-NOW. Use `get rs232.running` to check the live UART. | | `bridge.channel` | The 2.4 GHz channel, 1-13. Match it on both boards. This is separate from the LoRa frequency in `set radio`. | | `bridge.format` | `wrapped` is the default for this two-repeater setup and uses the shared secret. `raw` connects to primary-ESP-NOW nodes such as `Generic_ESPNOW` or `SenseCapIndicator-ESPNow`; it ignores the secret. Both peers must use compatible formats. | | `bridge.secret` | A matching, case-sensitive value of 1-15 characters for `wrapped` mode. It separates bridge groups; it is not strong encryption. MeshCore's own message encryption remains in place. | | `bridge.source` | `tx` crosses packets this repeater transmits on LoRa, after its forwarding decisions; use this for the setup above. `rx` crosses received packets before those decisions and can pass traffic the local repeater would not forward. | | `bridge.delay` | Wait before processing a packet received from the other bridge, in milliseconds. Range: 0-10000. Start with the default `500`. | | `repeat` | `on` enables normal LoRa forwarding; `off` disables forwarding. Keep it `on` on both bridge repeaters. Normal routing, scope, and packet-filter rules still apply. | | `bridge.type` | Read-only firmware capability, including combined transports. | | `espnow.running` | Read-only ESP-NOW runtime state. `on` means the local bridge started; it does not prove the other board is reachable. | This fork uses **`set bridge.source tx`** or **`rx`**. Some upstream guides use `logTx` and `logRx`; those are not the command values used here. For a LoRa gateway connected to primary-ESP-NOW Companions instead of another LoRa repeater, see [raw ESP-NOW compatibility](WiFi.md#wifi-companion-setup). ## 4. Check the link Run on both boards: ```text get espnow.enabled get espnow.running get espnow.status get bridge.channel get bridge.format get bridge.source get bridge.delay get repeat get radio ``` For the example above, expect enabled and running `on`, matching channel and format, source `tx`, delay `500`, repeat `on`, and the intended LoRa settings on each side. An existing `bridge.source rx` setup is also valid; diagnose the selected source rather than changing it just to match this example. Compare the shared secret privately; omit `get bridge.secret` from logs you share. `get espnow.status` distinguishes the configured channel from the actual 2.4 GHz channel. Its `last` error stage/code is historical and may remain after recovery. A running bridge is not proof that the other board received anything. Send a message from a Companion on network A to one on network B, then reply from B to A. Check both directions; configuration readback alone does not test delivery. If it does not work: - **Commands are unavailable:** check `get bridge.type` and the firmware choice. - **Enabled is on but running is off:** initialization failed. Reboot and check again; ensure another WiFi service is not occupying the radio. - **Both are running but traffic does not cross:** compare channel, format, and secret; confirm each board's LoRa settings were applied with a reboot, and check the networks' forwarding and scope rules. If those saved settings already match, use the bounded test below before changing them again. ### Test the 2.4 GHz path without LoRa forwarding Updated ESP-NOW bridge firmware includes runtime diagnostics in the ordinary image. No `BRIDGE_DEBUG` build flag or continuous USB logging is needed. Use the USB console so a WiFi change cannot disconnect your diagnostic session. On both boards, start a fresh observation window: ```text espnow resetstats get espnow.status get espnow.stats test ``` On A, send one probe: ```text espnow test A1B2C3D4 ``` `OK - test queued id=A1B2C3D4; confirm on peer` means queued locally. On B, run `get espnow.stats test`: `rx` must increase and `rxid` must be `A1B2C3D4`. Then send `espnow test B1C2D3E4` on B and confirm that ID on A. The two commands are two one-way tests; there is no automatic reply or retry. Sender completion alone does not prove peer receipt. The optional ID is exactly eight hexadecimal digits, without `0x`; omitting it uses the current uptime in milliseconds as a correlation ID. These small, unencrypted CRC-checked probes test transport reachability only. They do not validate packet-format compatibility or the wrapped shared secret, authenticate the peer or prove MeshCore packet delivery. They are never injected into the mesh or forwarded onto LoRa. Older firmware ignores them and cannot report the received ID; use an updated peer for confirmation. Sending a probe and resetting statistics require a local connection; neither changes saved preferences. ### Locate a mesh forwarding failure If both probe directions work, send one fresh identifiable message from a Companion on A's LoRa network and read these pages on both bridge boards: ```text get espnow.stats get espnow.stats rx get espnow.stats tx get espnow.stats drops ``` Repeat in the opposite direction with a new message. Counters accumulate until `espnow resetstats` or reboot and survive an ESP-NOW stop/start. Inspect changes across the one message, rather than assuming old totals describe the current attempt. Stopping or restarting clears pending queue work without classifying delivery; the TX drop counter records local rejection/final-failure decisions, not every undelivered packet. - **No source-side bridge TX request:** check the configured source. `bridge.source rx` exports LoRa receptions; confirm the board heard the fresh message. `bridge.source tx` exports LoRa transmissions; confirm it forwards the message with repeat on and the intended routing, scope and flood-filter settings. Either source is valid. - **TX requested but not sent:** the TX/drops pages separate queued traffic, filtering, duplicates, size/queue drops and SDK start/completion failures. Check the configured/live 2.4 GHz channel and last error stage/code. - **Peer sees frames but accepts no MeshCore packet:** inspect RX rejection counters, format and the privately compared wrapped secret. A successful diagnostic probe does not rule out a packet-format or secret mismatch. - **Peer admits the packet but no LoRa delivery follows:** admission means queued for normal mesh processing, not a completed LoRa transmission. Check repeat, scope, filters, duplicate suppression and the destination network. An absent counter change narrows a stage; these checks do not assume a cause for a particular pair of boards. If both bridge boards also hear the same message directly on LoRa, normal duplicate suppression can discard its later bridged copy. That alone does not show a broken ESP-NOW link. This is a possibility to check with the counters, not an established cause of a reported delivery failure. ### Optional short USB debug capture For a brief observation window, run `get usb.logging` and `get usb.debug` and record both original settings. Enable both gates with `set usb.logging on` and `set usb.debug on`. The bridge emits bounded `ESPNOW:` status/counter updates from its main loop, at most once per second when diagnostic state changes. No `BRIDGE_DEBUG` build flag is required, and WiFi callbacks do not print to USB. Send the two probes or one fresh message, then restore both original settings. The CLI counter pages and probes do not require either logging gate. Use the counter pages for exact values; a busy USB console can skip a debug update. Do not include secrets or WiFi credentials in a shared capture. A running bridge keeps the device awake, even with device power saving enabled. ESP-NOW shares the WiFi radio: use the connected WiFi network's channel when WiFi is active. Browser OTA pauses ESP-NOW on ordinary non-MQTT repeaters, reports that pause, and resumes saved-enabled ESP-NOW when OTA is stopped. A failed OTA start restores the bridge. The RS-232 transport remains available on combined boards while ESP-NOW is paused. For every command's full details, see the [bridge CLI reference](cli_commands.md#bridge-when-bridge-support-is-compiled-in). For a broader comparison with a Linux-based bridge, see the [MeshCore Nexus bridging guide](https://meshcore.nexus/guides/lora-bridging#method-2-meshcore-esp-now-bridge). ## Keep wardriving traffic off the bridge New generalized repeater filter tables include a third built-in rule that blocks authenticated `#wardriving` text and data in both bridge directions, at every hop count. The same row blocks crossover between radio profiles: ```text get flood.rule.3 set flood.rule type=any channel=#wardriving hops=all mode=bridge,cross drop ``` The same rule can be added with the shorter command: ```text set fr any c=#wardriving m=bc d ``` Both forms use the same table. `m=b` means bridge only, `m=c` means crossover only, and `get fr.N` returns a short command for copying a numbered rule. The unnumbered command adds the rule safely on existing devices whose saved tables predate this default. It works with either bridge packet source and both ESP-NOW formats. Nearby same-profile LoRa forwarding retains the separate four-hop default. Use `mode=bridge` for a bridge-only block, or `mode=cross` for a crossover-only block. See the [mode matrix and examples](flood_filtering.md#filter-bridge-and-radio-crossover-traffic).