Introduce a web configuration portal for easier node management and
provisioning without serial CLI. Enhance MQTT functionality with
improved IATA code validation, dynamic slot management, and
background NTP synchronization. Update web UI elements for better
user experience and security notes regarding open AP usage.
Continues restoring features dropped by the 22eb9b87 revert. Both were
upstream-tested code, not intentional fork removals.
CAD (hardware Channel Activity Detection / listen-before-talk before TX),
fully restored and functional:
- NodePrefs.cad_enabled + `set cad on/off` / `get cad` CLI (default off)
- RadioLibWrapper: _cad_enabled + setCADEnabled() + the scanChannel()/CAD
branch in isChannelActive() (Phase 1 already restored the Dispatcher hook)
- getCADEnabled() overrides in the repeater/room/sensor apps (return the
pref) and companion (always on, matching upstream)
radio_fem_rxgain: the NodePrefs field + /com_prefs persistence are restored
here at upstream's exact offsets (293 fem, 294 cad), which makes /com_prefs
byte-identical to upstream through the tail. The field is persisted and
defaults on (upstream default), but the per-board LNA *driving* + the
`radio.fem.rxgain` CLI are deferred to the FEM-hardware change (they depend
on board methods and want per-board bench testing).
The new-format /com_prefs tail grows from 3 to 5 bytes; the old-format
detection threshold and the host migration harness are updated accordingly
(all scenarios pass, incl. the non-MQTT-build variant).
Builds: Heltec_v3 repeater, repeater-observer, room-observer. (sensor /
plain-room / companion fail only on the pre-existing Timezone.h include
issue, unrelated to these changes.)
Refactored the handling of observer-related settings by moving them from
NodePrefs to a new MQTTPrefs structure. This change centralizes MQTT,
WiFi, timezone, SNMP, and alert configurations, improving code organization
and maintainability. The new structure allows for better separation of
concerns and prepares the codebase for future enhancements.
Implemented new commands for configuring and diagnosing NTP server
settings in the MQTT bridge. Users can now set a custom NTP server
and probe connectivity to configured servers. This enhancement
improves time synchronization reliability for JWT authentication
and provides better diagnostics for NTP connectivity issues.
Updated the fault alert functionality to include an optional region name for scoping alert floods, allowing operators to override the default scope. Introduced a list of banned channels (e.g., Public PSK, `#test`, `#bot`) to prevent spamming community channels with alerts. The implementation ensures that alerts are only sent to private PSKs or non-banned hashtags. Relevant changes were made across multiple files, including updates to the CLI for setting and retrieving the new `alert.region` preference.
* room server: added RegionMap, and new CommonCLI wiring, default_scope handling
* sensor: only minimal RegionMap wiring. Still needs work to handle default-scope
Reverted prior dev merge, then merged current meshcore-dev dev. Resolved
CommonCLI by restoring MQTT prefs flow with upstream com_prefs layout
(rx_boosted_gain at offset 79), rxgain CLI, poweroff/shutdown, and FEM
variant files from upstream.
Made-with: Cursor
Resolve conflict in heltec_tracker_v2/platformio.ini: keep
SX126X_REGISTER_PATCH=1 from upstream and retain GC1109 comment.
Co-authored-by: Cursor <cursoragent@cursor.com>
- Added formatStatsReply, formatRadioStatsReply, and formatPacketStatsReply methods in MyMesh for both simple_repeater, simple_room_server, and simple_sensor.
- Updated CommonCLI to handle new stats commands.