The room server never supported RX boosted gain, while the repeater
does. Three consequences on SX1262/SX1268 boards:
- boosted gain was never applied to the radio at boot, so a room server
ran in power-saving RX mode while an identical repeater ran boosted -
a real receive-sensitivity difference with nothing pointing at it
- _prefs.rx_boosted_gain was never initialised (the prefs are memset to
0 before defaults are set), so it defaulted to off
- 'set radio.rxgain on' replied "Error: unsupported" but CommonCLI had
already written the value to prefs and saved them, so a stale setting
survived reboot and was never applied
Mirror the repeater's implementation: initialise the pref default under
the same USE_SX1262/USE_SX1268 and SX126X_RX_BOOSTED_GAIN guards, apply
it during radio init, and override setRxBoostedGain() so the CLI reports
success and takes effect.
Built Heltec_v3_room_server (SX1262) and LilyGo_T3S3_sx1276_room_server
(guards compile out cleanly).
Implement SNMP functionality in MyMesh to provide radio diagnostics
and statistics updates. This includes a new method for formatting
radio diagnostic replies and periodic updates to the SNMP agent
with radio stats, enhancing monitoring capabilities for users
with SNMP enabled.
(cherry picked from commit fbe608d6c0)
Implement SNMP functionality in MyMesh to provide radio diagnostics
and statistics updates. This includes a new method for formatting
radio diagnostic replies and periodic updates to the SNMP agent
with radio stats, enhancing monitoring capabilities for users
with SNMP enabled.
Add functionality to schedule deferred OTA updates in the MyMesh class.
This includes a new member variable to track the update time and a method
to initiate the update process, allowing for a smoother OTA experience
by managing timing and state transitions effectively.
Cherry-picked from observer-firmware (76f44d7d). Resolved a conflict in
loop() where the WITH_WEBCONFIG block occupies the same anchor and shares
an identical closing tail; both blocks retained.
Add functionality to schedule deferred OTA updates in the MyMesh class.
This includes a new member variable to track the update time and a method
to initiate the update process, allowing for a smoother OTA experience
by managing timing and state transitions effectively.
Introduce a new built-in MQTT preset for the meshtexas.org service,
increasing the total number of presets to 29. This addition enhances
connectivity options for users and supports broader integration
within the MQTT ecosystem.
Enhance the MQTT stats reply to include outbox drop statistics,
providing users with better insight into message handling and
memory pressure. This change improves the clarity of the status
message and aids in diagnosing potential issues with message
delivery.
Update the CommonCLI_Observer to mask sensitive data such as passwords
and WiFi credentials in responses when accessed remotely. This change
ensures that sensitive information is only visible over serial,
enhancing security and preventing accidental exposure of credentials.
Improve the response message for the `alert test` command to clarify
that a successful test send does not guarantee automatic alerts are
enabled. This change helps prevent confusion for operators regarding
the status of the alert system after testing.
Implement logic to determine the maximum number of active MQTT slots
based on available memory. This change allows the system to warn users
when attempting to connect more slots than supported by the hardware,
improving user experience and preventing connection issues. The logic
is centralized in the new getMaxActiveSlots() method, ensuring
consistency across the codebase.
Add a new classification mechanism for MQTT slot activation to inform
users whether a slot will connect on the current hardware. This includes
detailed handling of enabled slots and their limits, improving the CLI's
ability to provide accurate feedback during configuration. Additionally,
unit tests are introduced to validate the new functionality across various
scenarios, enhancing overall robustness.
Adjust the command handling in CommonCLI_Observer to prioritize the
more specific "timezone.offset" check before the general "timezone"
check. This change prevents incorrect responses when querying the
timezone offset, improving the clarity and correctness of command
responses.
Enhance the command handling in CommonCLI_Observer to clarify the
compilation behavior under different configurations. Additionally,
optimize memory pressure checks in MQTTBridge to reduce unnecessary
heap walks, improving performance during sustained memory pressure.
This change ensures that publishes are skipped only when necessary,
enhancing overall stability.
Eliminate unnecessary calls to gmtime and localtime in the
syncTimeWithNTP function. This cleanup improves code clarity
and reduces potential confusion regarding time handling.
Add checks to prevent null or zero-length hex buffers in the
bytesToHex and packetToHex functions. This guarantees that an
empty string is returned instead of an uninitialized buffer,
improving the safety of JSON serialization.
Introduce a mechanism to manage on-connect status publishing for MQTT
slots. This change allows the MQTT task to handle status updates
safely, ensuring that shared resources are accessed in a controlled
manner. The new flag `_status_publish_pending` is set in the onConnect
callback and processed in the main MQTT task loop, preventing race
conditions and improving overall stability.
Replace multiple snprintf calls with a single replyAppendf function to
improve buffer management and prevent overflow. This change enhances
the readability and maintainability of the code while ensuring that
the reply buffer is handled safely across various MQTT status and
diagnostic replies.
Enhance the documentation for the `start ota` command to clarify its
behavior when connected to a Wi-Fi network versus when using the
`start ota ap` option. This provides users with better guidance on
how to initiate OTA updates under different network conditions.
(cherry picked from commit 2019a8c0ca)
Enhance the documentation for the `start ota` command to clarify its
behavior when connected to a Wi-Fi network versus when using the
`start ota ap` option. This provides users with better guidance on
how to initiate OTA updates under different network conditions.
Add support for neighbor discovery and management in the MyMesh class.
This includes structures for neighbor information, methods for handling
neighbor advertisements, and control data reception. The new features
allow for dynamic neighbor management, enhancing the mesh network's
capabilities. Additionally, the maximum number of neighbors is set to
50 across various platform configurations.
Added functionality for neighbor discovery, including the ability to
store and manage neighbor information. This includes methods for
sending discovery requests, handling responses, and updating the
neighbor table. The changes enhance the mesh networking capabilities
by allowing devices to discover and interact with nearby peers more
effectively. Updated relevant structures and methods in MyMesh.cpp
and MyMesh.h to support these features.