An unconfigured slot has an all-zero secret, so it matches null-key group traffic (a sender with an unset PSK). The zero-key MAC validates against the empty slot and the foreign message is delivered as if it belonged to that channel — every node with a free slot is a null-key sink. Skip empty slots.
thinknode_m8: initial support
adds some functionalities to ui_task and epddisplay:
epd display,
- supports screen off, and clear screen
- supports forcing full refresh every N partial refreshes (off by default, configured to 60 for M8)
ui_task
- UI_SHOW_CLOCK flag to display clock on first screen
- rotary button can act like joystick (with regards to Enter key), defaults to old config for existing nodes
- screen off on long press when using rotary button (very handy for the watch)
Grove and other Bosch modules strap SDO high, so the 0x76-only table
never initialized them. Add an alternate-address entry per Bosch sensor;
the bus scan still gates every probe, and all four drivers verify a chip
ID before claiming an address.
Each sensor type has a single static driver instance, so skip an entry
whose query is already active: the alternate address is a fallback, not
a second device.
Several table entries share an address and not every driver verifies a
chip ID: INA226::begin() only checks that the address ACKs, so an SHT4x
at 0x44 was also registered as an INA226 and reported junk current on a
second channel. Mark the address consumed once a driver initializes it
so later entries cannot re-claim the same device.
MAX_CLIENTS is defined in both src/helpers/ClientACL.h and examples/simple_repeater/MyMesh.h. Appears it was centralised in the former header file some time ago. Both are included in some places and, depending on which order they're in, either value can win.
This change drops the duplicate entry from the repeater firmware and bumps the central limit up to 32 (per the original repeater firmware value).
Changes:
- Remove MAX_CLIENTS from repeater MyMesh.h
- Increase MAX_CLIENTS limit in ClientACL.h to 32