Replace obsolete reader-timeout and message-thread source assertions with
compiled regressions for bookmark saving across battery/USB transitions and
newest-visible message summaries in History, Pending, and Unread modes.
Extend the MQTT sleep harness with dual-radio state and verify both blockers
release when disabled. All 19 post-native verification groups pass on Linux,
including the complete UI and browser runtime suites.
Implement radio2, tempradio2, radioat2 and tempradioat2 across Mesh roles,
with RX-only/RX+TX operation, optional preambles and persistent cross-TX
policy. Keep temporary OTA traffic on its profile by default and maintain
independent retry ownership and backoff for each profile.
Use slow-first receive scanning with 4.8-symbol visits and automatic
preambles rounded up in steps of eight. Preserve pending RX, restore power
saving on exit, and discard work bound to changed or expired profiles.
Restore the infrastructure path.hash.mode setter and report unsupported
extra.sf settings consistently. Add CLI, scheduling, scan and retry tests,
setup documentation, and the V4/XIAO hardware validation results.
Validation: 1,422 native tests, eight KISS tests, 63 final focused profile
tests, 18 checks from the staged source, sanitizer-enabled OTA transfers,
and builds for V4 Mesh roles, Full XIAO Companion and nRF52 T1000-E.
Hardware checks cover reception, cross-TX policy, expiry, reboot and OTA
discovery while receiving main-channel adverts.
One nRF52840 variant shared across both radios, picked per env: Duo runs
the LR1121, Uno the SX1262. Same PCB, only the radio and its DIO1 pin
change.
SuperIO adds the SH1107 OLED, GPS, buzzer and joystick. GPS is driven by
the 3-position mode switch (Mode 2 = on), polled live the way thinknode_m1
does it.
Five quick user-button presses power the unit off; a press wakes it back
on (arms the button as an nRF52 GPIO SENSE source before SYSTEMOFF).
Consolidates #2054 and andyshinn's shared-base/uno work, rebased on dev.
Co-authored-by: lbibass <ewdries02@gmail.com>
Co-authored-by: Andy Shinn <andys@andyshinn.as>
Use RX-only radio recovery and feed the repeater reboot watchdog after MeshCore parsing. Default to 24 hours, apply temporary watchdog and advert intervals in RAM, and report temporary durations as days, hours, and minutes. Add regression coverage and an ESP-NOW bridge setup guide.
Integrate ExpressLRS TX module support and its stacked ESP32 heap changes.
Use the approved Linkflow calibration (17-30 dBm), preserve the PA drive
and output path after radio recovery, and keep LoRa OTA enabled.
Preserve stored ACLs and filters on allocation failure, release owned
client/filter buffers, service heap OTA contexts on Companions, release
self-serving workspaces after TempRadio, and reset staged-resume state
when a context is released. Keep manual staging and active operations
alive. Account for all moved allocations in the runtime RAM gate.
Validation: 1,393 native cases; radio-power, heap-context, ACL persistence,
shared-queue transfer, display/inbox, radio receive, and memory regressions.
Firmware builds passed for Linkflow, Heltec V2 Companion, T-Beam MQTT
repeater, Heltec V4 R8 MQTT repeater, RAK4631 repeater, and Indicator Full.
Physical verification awaits access to the currently offline lab Pi.
Default to retained history with a separate pending count, and add persistent display.inbox CLI modes for history, pending, and unread. Preserve browsing while clients are connected and show the active USB or Bluetooth connection.
Fixes#5
Persist separate display modes and timeouts in seconds for battery and USB power, expose four controls in WebConfig and CLI, and apply one shared policy across display-equipped roles.
Detect R8 external power from a USB host or calibrated battery voltage above 4.21 V, with cached sampling and hysteresis. Add policy, persistence, browser, and R8 power-detection regression coverage.
Accept the upstream empty-prefix neighbor.remove command after whitespace normalization while preserving invalid-key checks. Cover repeater and room-server removal paths with regression tests.
Fixes#8
Hardware captures show that a median and lower quartile can follow the interferer while the 12.5th percentile retains the quiet floor. Use that estimate with existing weighting and bounded rise recovery. Wait for settling after every RX re-arm and allow thirty seconds for a complete idle-sample block.
Add captured-sample, low-tail limitation, and real CLI setter regressions. Preserve RXPS intent when parsing an off command with trailing whitespace. All 162 native cases and 24 Python regressions pass.
Port the measured RXPS model without changing Cascade wire preambles or automatically enabling experimental levels. Use a spaced weighted median with bounded calibration windows, preserve packet ownership across CAD, and check actual SX126x receive mode before recovery.
Preserve Cascade sleep and radio fixes, integrate the new sensor and board profiles, and correct BSEC script inheritance and the MKE UART pin conflict. Native regressions, production-method/SPI harnesses, and ESP32, nRF52, and STM32 builds pass. Hardware comparison and fault-injection validation are recorded privately.
List limited public-key prefixes, reasons, and wait times in bounded pages, with full-key details for targeted clearing. Queries preserve quotas and recovery timers.
Validated with 71 native tests, Full repeater and room-server builds, and a 909.500 MHz RF test covering 10 forwarded adverts, 2 blocked adverts, and forwarding after targeted clear.
The review asked for the pinned SNTP implementation's response checking to be
established rather than assumed. It is `SNTP_CHECK_RESPONSE = 0`: the lwIP
default in `lwip/src/include/lwip/apps/sntp_opts.h`, not overridden in this
build's ESP32 `lwipopts.h` or any sdkconfig — and lwIP ships precompiled in the
SDK, so no `-D` of ours can change it. At 0 it checks neither that the reply came
from the server it queried nor that the originate timestamp matches the request
it sent. Those are two of the checks that make the new validated probe
trustworthy, so SNTP was strictly weaker than the path it backed up.
It was reachable three ways, all of which set the system clock:
- the fallback inside `syncTimeWithNTP()`, which ran precisely when the
validated probe had failed — i.e. when interference is most likely;
- `refreshNTP()`, hourly, for the life of the node;
- `configTime()` after a *successful* validated sync, whose timezone side effect
was all that was wanted but which also left a background SNTP poller running
that would go on accepting unvalidated replies.
All three are gone. The periodic refresh runs the same validated probe as every
other sync, and the timezone is set directly with `setenv("TZ", "UTC0")` +
`tzset()`. Nothing is lost operationally: SNTP queried the same servers over the
same UDP/123 with a weaker parser. The RTC/system-clock fallback is a separate
decision and stays.
Review of the branch found one merge-blocking lifecycle hole and three
correctness gaps where the implementation stopped short of contracts the design
had already written down. All four are real; each was confirmed against the
source (two of them against hardware) before anything changed.
**P1 — a quarantined client could still produce a clean bridge stop.** The
cooperative teardown set `_teardown_complete` unconditionally, so a slot whose
`esp_mqtt_client_stop()` had not completed — deliberately skipped by
`destroySlotClients()` and marked Quarantined — still let the trampoline publish
the acknowledgement. The owner then freed the queue and buffers and allowed a
restart while that SDK task might still be running: exactly the ownership
ambiguity StopUnproven exists to remove. The ack is now withheld unless EVERY
client is proven stopped, so one unproven client leaves the whole bridge
unproven. The rule lives in MQTTClientState.h (`mqttStopMayBeAcknowledged`) with
host tests, alongside the state predicates moved out of the bridge.
**P2 — the F04 protection did not cover a client that was still connecting.**
`softDisconnect()` returns ESP_OK immediately when the client is not connected,
so for a slot mid-DNS/TLS/CONNECT it cancelled nothing: the attempt ran on and
its CONNECTED event arrived after the new configuration was applied, and with
callbacks registered once per client and esp-mqtt events carrying no generation,
nothing could tell it from the new attempt's. A reconfigure that lands on a
`Starting` client now stops it, joining its SDK task, before applying the new
configuration. A Connected client still takes the cheap softDisconnect path,
which is where the fragmentation argument applies. One helper
(`closeLiveClientForReconfigure`) so the two call sites cannot drift.
**P2 — a failed renewal bounce still advanced the effective expiry.** Minting
updates `token_expires_at` immediately and the renewal decision read it, so a
bounce that failed looked complete: the next pass saw a fresh future expiry and
never retried, and clearing `last_token_renewal` re-armed nothing. Slots now
carry `applied_token_expires_at` — the expiry of the credential the CONNECTION
is using — which only advances when a connect or reconnect has carried it. A
failed bounce leaves it on the old credential, so the renewal stays due.
**P2 — config-committed and start-accepted were conflated.** `connect()`
returned one result for both, so a start that failed after the configuration had
committed left `applied_config` describing the previous configuration, and the
next recreate-or-reuse decision could reuse a client whose trust policy was not
the one it believed. `applyConfig()` is now its own wrapper operation;
`applied_config` records the commit, activation records the start. The reconnect
ladder resets there too rather than in `teardownSlot()` — the old endpoint's
history still applies until a replacement configuration actually commits.
Two of my own bugs surfaced on hardware while testing this, both fixed here:
- `recreateSlotClient()` called the full `teardownSlot()`, which cleared
`broker_uri`, the just-minted token and both expiries out from under a
configuration that had already been decided, so a recreate handed the SDK an
empty URI and an empty token. It now stops the client and swaps the object,
touching nothing else, and the apply step refuses to configure a URI that
changed under it rather than passing it on.
- `stopSlotClient()` quarantined on any non-OK result, but `ESP_FAIL` from
`esp_mqtt_client_stop()` means "client is in invalid state", i.e. not started:
there was no task to join, the safest state there is. It was observed
quarantining healthy clients on hardware. The case that genuinely cannot be
proven is a stop that never RETURNS, which cannot surface here at all — it
hangs the task, which is what the bridge-level timeout contains.
Hardware (Heltec V4, 5 live slots): a reconfigure landing on a connecting client
logs `reconfigure during connect - stopping to cancel the attempt`; a broker
holding the CONNACK sees the client close the socket and the disabled slot never
connects; `wss`→`mqtt`→`wss` recreate cycles reconnect each way; a blackholed
endpoint recovers. 499/499 native tests, four envs clean.
The stale-configuration fix, and the reason the four preceding commits went
first.
`setupSlot()` applied configuration field by field, interleaved with the
decisions that produced it, and cleared stale fields only when
`slot.initial_connect_done` was set — which `teardownSlot()` clears at the top
of every reconfigure. So live reconfiguration always skipped the cleanup. On a
5-slot board this was reproducible in one command: moving a slot from a JWT
preset to an anonymous custom endpoint sent the previous configuration's
`v1_<pubkey>` username in the CONNECT to the new broker (95-byte CONNECT
captured at a throwaway broker on the LAN). The same config after a reboot sent
26 bytes with no username, which is what pinned it to the reconfigure path.
That cleanup could not have worked anyway: it nulled the wrapper's pointers, and
IDF's `esp_mqtt_set_if_config()` treats NULL as "leave unchanged", so an
SDK-held credential survives it. An empty string does overwrite it, and leaves
the CONNECT's username flag clear.
So configuration is now decided in full first, then applied in one place:
- every owned field is written on every apply — server, trust material,
username, password — with absent credentials written as "" rather than
omitted;
- `mqttConfigRecreateDecision()` (previous commit) picks reuse or recreation.
Credentials, auth-mode changes and endpoint moves within one scheme reuse the
client, because a create/destroy cycle on the reconnect and renewal paths is
the fork's documented internal-heap fragmentation driver. A transport
(scheme) change, a trust-policy or CA change, and buffer-capacity growth
recreate it, because those are the fields a write cannot safely replace;
- `recreateSlotClient()` will not destroy a client whose stop was not proven —
it quarantines it and fails the setup instead;
- the applied configuration is recorded only after the client actually starts.
Verified on hardware (Heltec V4, 5 live slots, both paths):
- reuse path — a custom JWT slot (639-byte CONNECT carrying `v1_<pubkey>` plus
the token) with its audience cleared now sends 26 bytes with no credentials,
with no client recreation;
- recreate path — `mqtt://` to `wss://` logged `recreating client
(transport-change)` and reconnected.
Also fixes a cap regression the hardware run caught: `canActivateSlot()` now
counts the positions held by the *other* slots. A slot being reconfigured keeps
its esp-mqtt task alive, so once the count included live clients it counted
itself out of its own position and a full board refused to reconfigure a slot —
disabling it instead. Asking "is there room for this slot" rather than "is
there room for one more" is also what makes a resource-based count safe.
`client->connected()` answers "is the network up", and it was being used for
"is there anything to stop". A client resolving DNS, negotiating TLS or waiting
after a failed CONNECT reports not-connected, so `teardownSlot()` skipped it:
selecting `none` cleared the bridge flags while the SDK task kept running, and
when the in-flight handshake completed the callback marked the disabled slot
connected and scheduled its status.
Each slot now carries the client's SDK lifecycle state (Absent, Configured,
Starting, Connected, Disconnected, Stopped, Quarantined) and a generation
counter for the logs. The bridge task owns that state, which makes it the
authority the callbacks consult:
- a CONNECTED event for a slot that is disabled, never started, or already
stopped is logged and dropped instead of marking the slot connected;
- teardown stops any *live* client, so a mid-handshake client can no longer
outlive its configuration.
Teardown also gains a reason, because "stop the task" and "close the transport"
are different needs:
- `Disable` (preset `none`, shutdown) stops the client — the stop is the point;
- `Reconfigure` closes the transport with `softDisconnect()` and keeps the
esp-mqtt task. Stopping it there would return its 6 KiB stack into the hole
the two 16 KiB mbedTLS record buffers just vacated, which is the fork's
documented internal-heap fragmentation driver — and per the soak campaign's
own conclusion, feeding `softDisconnect()` into the reconfigure path is the
fix for it, not serialisation. The campaign closed 2026-08-20, so the
reconfigure churn is no longer anyone's measurement lever.
A stop that does not complete now quarantines that client: its SDK task was
never joined, so it is never reused, never destroyed, and the token buffer its
config still points at is never freed. `get mqttN.diag` reports `quarantined`.
Two knock-ons this required:
- `setupSlot()` starts or reconnects according to the SDK state.
`esp_mqtt_client_start()` fails on an already-started client, and now that
its result is honoured, a reconfigure that kept the task would otherwise
leave the slot permanently unactivated.
- the active-slot cap counts resource holders as well as configured ones. It
keyed off `initial_connect_done`, which teardown clears, so a started or
quarantined client stopped counting against the cap and a board could
oversubscribe past the concurrent-TLS limit the cap exists to enforce.
`connect()`, `reconnect()`, `disconnect()`, `softDisconnect()` and `forceStop()`
all returned void, so every caller in the bridge treated "asked" as "done":
- `setupSlot()` marked a slot activated after `connect()` whatever happened. A
failed `esp_mqtt_client_start()` therefore consumed one of the scarce
active-slot positions, handed the slot to a reconnect ladder that is gated on
activation, and was never retried by the deferred-setup path.
- `reconnect()` explicitly proceeded after `esp_mqtt_set_config()` failed,
reconnecting on the previous configuration — the renewed token in the buffer,
the old one on the wire.
- the renewal path recorded the new expiry before the bounce succeeded, so a
failed bounce left the live session on the old credential with the next
renewal not due for a whole token lifetime.
- `softDisconnect()` logged its timeout and told its caller nothing.
- `disconnect()` waited for the DISCONNECTED event with no bound, on the very
task whose stop acknowledgement the shutdown waits for.
Now every one of them returns `esp_err_t`, a failed configuration transaction
aborts rather than starting or reconnecting on a half-updated config, and
`disconnect()`'s wait is bounded (it still stops the client, and reports
ESP_ERR_TIMEOUT when the event never arrived).
Bridge consequences:
- a failed start leaves the slot unactivated, so the existing deferred-setup
retry revisits it and it holds no active-slot position;
- a failed renewal bounce re-arms the renewal instead of recording it, so the
next maintenance pass retries;
- a reconnect that fails *locally* rolls back the backoff advance made for it.
The ladder and the breaker bound broker and network faults; an uninitialised
client or an uncommitted config transaction is neither, and inflating the
ladder for it was how a local fault could trip a breaker meant for a broker.