@@ -4028,6 +4028,26 @@ This setting is used only by `bridge.format wrapped`; raw mode ignores it.
|
||||
#### View the bootloader version (nRF52 only)
|
||||
**Usage:** `get bootloader.ver`
|
||||
|
||||
Applies to every nRF52 board/role that exposes this getter, including Companion,
|
||||
repeater, and room-server firmware. It reads the installed bootloader region
|
||||
selected by the MBR/UICR boot address and bounded by the chip's flash geometry;
|
||||
it does not search application firmware or staged update files.
|
||||
|
||||
The reader preserves a complete Adafruit/UF2 version string, including OTAFIX,
|
||||
preview, and vendor/build suffixes. If that string is absent or ambiguous, it
|
||||
uses the existing whole-image CRC and unique BLMF/BLM2 validation to read the
|
||||
embedded OTAFIX version (for example, `> OTAFIX2.4.6`). Some current release
|
||||
images, including MeshTower V2 SD 2.4.6, omit the UF2 text entirely. As a last
|
||||
fallback, the Adafruit core's startup-captured version is explicitly labelled
|
||||
`(base)`; it cannot identify an OTAFIX/fork revision.
|
||||
|
||||
`unknown` remains possible for a bootloader exposing none of these version
|
||||
sources, invalid geometry/vectors, or unresolved ambiguity. There is no universal
|
||||
version field shared by every third-party bootloader. This is diagnostic only:
|
||||
displaying a version neither grants OTA capability nor bypasses install checks.
|
||||
The fix is in MeshCore application firmware; installing another bootloader alone
|
||||
does not update an older application's version reader.
|
||||
|
||||
---
|
||||
|
||||
#### View power management support
|
||||
|
||||