Harden LoRa OTA automation retries
This commit is contained in:
1 parent
26d6e0f99a
commit
e47e028b6d
3 files changed
+1107
-114
No files matched your search
@@ -340,14 +340,50 @@ the destination.
|
||||
hash, version, and nRF52 bootloader capabilities.
|
||||
3. Select or build one compatible mOTA and verify all block hashes, Merkle
|
||||
root, full-image hash where applicable, identity fields, signature, codec,
|
||||
and base.
|
||||
base, and the firmware's 1024-byte maximum block size.
|
||||
4. Save the controller's normal radio tuple and show the confirmation prompt.
|
||||
5. Start TempRadio on the target, then far-to-near relays, then the source;
|
||||
finally switch the controller to the same tuple.
|
||||
finally switch the controller to the same tuple and read it back. The runner
|
||||
rejects a TempRadio window that cannot cover setup, seeder startup,
|
||||
discovery, the transfer timeout, final polling, and install checks.
|
||||
6. Start `motatool serve`, discover the exact eight-hex manifest ID, request
|
||||
`ota pull <id> flash`, and poll until the target reports ready.
|
||||
7. Request `ota install`, restore the controller's original radio, wait for
|
||||
reboot, then query the new running identity and version.
|
||||
`ota pull <id> flash`, and poll until that same ID reports ready. A seeder
|
||||
process exit stops the run immediately.
|
||||
7. Recheck that exact ID, give the target a short final TempRadio safety window,
|
||||
and request `ota install`. Then shorten each relay's TempRadio window so the
|
||||
normal multi-hop route returns, restore the controller, wait for reboot, and
|
||||
require the new running identity and exact package version.
|
||||
`--leave-controller-radio` moves the controller back to TempRadio only after
|
||||
this normal-channel verification.
|
||||
|
||||
Remote replies are matched only after queued messages have been drained and
|
||||
only when they come from the intended contact and fit the command. A ready
|
||||
status for another manifest ID is an error, never permission to install it.
|
||||
|
||||
## Transmission loss and retries
|
||||
|
||||
Read-only and replay-safe transmissions retry up to three times. Three retries
|
||||
or 90 seconds, whichever comes first, opens a 10-second stop-or-continue
|
||||
prompt. Continue is the default on timeout, Enter, and unattended input, so a
|
||||
temporary outage does not silently abandon a resumable transfer. Enter `s` or
|
||||
`stop` to end the run; Ctrl-C also remains immediate.
|
||||
|
||||
Commands that change OTA state are reconciled before replay:
|
||||
|
||||
- After a lost `ota pull` reply, `ota status` must show the requested manifest
|
||||
ID before the runner treats the pull as started. Otherwise the safe retry
|
||||
policy applies.
|
||||
- A lost `ota install` reply is not blindly resent. After a short wait, it is
|
||||
sent again only if the target replies that the same manifest is still ready.
|
||||
If the target has stopped replying because it may be rebooting, the runner
|
||||
restores the normal path and lets post-reboot identity resolve the outcome.
|
||||
The target's final three-minute safety window also returns a non-rebooting
|
||||
target to the normal channel promptly.
|
||||
|
||||
Retries and operator-selected continuation can outlast the original TempRadio
|
||||
budget. If a bounded window expires, rerun the same package after the nodes
|
||||
return to their normal channel; the manifest-ID check resumes its partial
|
||||
download without replacing it.
|
||||
|
||||
The working directory is retained and printed at exit. It contains the exact
|
||||
served mOTA, `motatool-serve.log`, extracted build inputs when needed, and
|
||||
@@ -376,10 +412,12 @@ $radio = (Get-Content '.\meshcore-lora-ota-...\controller-radio.txt' -Raw).Trim(
|
||||
meshcli -s COM7 set radio $radio
|
||||
```
|
||||
|
||||
If installation was accepted but the final confirmation timed out, reconnect
|
||||
on the node's normal channel and run `ota self` and `ver`. Do not immediately
|
||||
replace a staged image: the default active-download guard preserves it until
|
||||
you explicitly use `--replace-active-download` or run `ota cancel`.
|
||||
If you stop during final confirmation, reconnect on the node's normal channel
|
||||
and run `ota self` and `ver`. A completed run returns success only when
|
||||
`ota self` reports a valid new body hash and `ver` exactly matches the package;
|
||||
an unverified install returns status 2. Do not immediately replace a staged
|
||||
image: the default active-download guard preserves it until you explicitly use
|
||||
`--replace-active-download` or run `ota cancel`.
|
||||
|
||||
Exit status is `0` for success, `2` for a validation or operational error, and
|
||||
`130` for Ctrl-C.
|
||||
Reference in new issue
Block a user