Honor saved WebUI off during unconfigured boot setup
An enabled MQTT bridge without a saved SSID forced WebConfig back on at boot, even after set webui off. Its setup AP also suspended an enabled ESP-NOW bridge. Use first-time MQTT setup as the default only when no WebUI choice is saved. Apply the saved on/off setting afterward in Repeater and Room Server. Preserve first-time provisioning and explicit starts. Add executable boot regressions for both roles with unset, on and off WebUI settings and configured/unconfigured WiFi. Update setup and picker guidance.
This commit is contained in:
1 parent
16399a019d
commit
af69918094
7 files changed
+87
-20
No files matched your search
@@ -305,7 +305,9 @@ the no-output and USB settings because `set usb.logging off|on` is persistent.
|
||||
On a fresh unified FULL install with no saved SSID, the setup AP and WiFi radio
|
||||
remain available for 30 minutes per boot, then turn off automatically until the
|
||||
next reboot or power cycle. An explicit administrator `start webconfig` remains
|
||||
available as an override. A saved SSID switches to the normal indefinite
|
||||
available as an override. Save `set webui off` to close the portal and prevent
|
||||
its automatic return after reboot, including on an ESP-NOW node without WiFi
|
||||
credentials. A saved SSID switches to the normal indefinite
|
||||
reconnect behavior instead.
|
||||
|
||||
Fresh ESP32 Full infrastructure defaults to USB logging off. Existing saved
|
||||
|
||||
Reference in new issue
Block a user