Evaluate mesh clock when quorum arrives

This commit is contained in:
mikecarper committed 2026-07-23 11:20:07 -07:00
1 parent 468e7846bd
commit abd2d3b7a8
3 files changed
+49 -18

No files matched your search

+16 -11
View File
@@ -610,17 +610,20 @@ send text.flood checking ridge link
- `clock.sync.samples`: `9`
When either source is enabled, the repeater makes its first clock-bootstrap
attempt after 30 minutes of uptime. A successful estimate changes the RTC only
when the absolute difference is **greater than** `clock.sync.drift`; correction
can move the clock forward or backward. A valid estimate within the threshold
counts as a successful sync without changing the clock. Seven days after each
successful estimate, the repeater evaluates time again; the seven-day deadline
therefore starts from the last successful estimate rather than from boot. This
is a lazy uptime deadline: the check runs on the first normal loop/wake after it
becomes due and does not wake the device by itself. If no source or consensus is
available, the repeater retries every 30 minutes until one succeeds, then starts
a new seven-day interval. Every reboot starts with the initial 30-minute attempt.
An existing saved setting always overrides the platform default.
attempt after 30 minutes of uptime, or immediately when the configured number
of fresh evidence sources has been collected, whichever comes first. A
successful estimate changes the RTC only when the absolute difference is
**greater than** `clock.sync.drift`; correction can move the clock forward or
backward. A valid estimate within the threshold counts as a successful sync
without changing the clock. Seven days after each successful estimate, the
repeater evaluates time again; the seven-day deadline therefore starts from the
last successful estimate rather than from boot. This is a lazy uptime deadline:
the check runs on the first normal loop/wake after it becomes due and does not
wake the device by itself. If no source or consensus is available, the repeater
retries every 30 minutes, and newly collected evidence triggers another
immediate evaluation once the configured source count is present. Every reboot
starts with the initial bootstrap attempt. An existing saved setting always
overrides the platform default.
`clock.sync.mesh now` bypasses the startup/seven-day deadline and queues a
LoRa-only consensus evaluation on the next normal loop, even when the internet
@@ -629,6 +632,8 @@ source is also enabled. It uses any currently fresh samples without clearing the
and the next attempt follows the normal 30-minute retry. The command requires
`clock.sync.mesh` to be on and does not bypass CLI, GPS, or NTP suppression; it
also retains the normal quorum, timestamp-validity, and drift checks.
The separate `clock` command only displays the current RTC and does not request
a synchronization attempt.
`clock.sync.mesh` collects signature-verified advert timestamps and MAC-valid,
decrypted Public-channel plain-text timestamps. In normal path mode, collection