Add persistent battery ADC calibration across boards
Add meter-reference calibration with saved ADC corrections, checked persistence and rollback. Preserve existing board coefficients and nRF52 voltage policy, and merge the Mini Repeater feature gates. Validation: 69 focused tests, hosted documentation checks, and four firmware builds passed. Mini Repeater retains calibration and its existing filesystem with 376 flash bytes free; earlier Mini Sensor size failures remain documented.
This commit is contained in:
1 parent
94a3b7e568
commit
ab6412e73c
108 files changed
+1303
-83
No files matched your search
+49
-3
@@ -2526,6 +2526,49 @@ sessions. Setting the password to `off` makes it the literal password `off`.
|
||||
|
||||
---
|
||||
|
||||
#### Calibrate the battery reading against a meter
|
||||
|
||||
**Availability:** Repeater, Room Server, Sensor, Companion and Terminal Chat
|
||||
firmware on boards with a supported battery ADC. Use an administrative CLI
|
||||
connection; infrastructure roles also accept authenticated remote commands.
|
||||
|
||||
```text
|
||||
battery calibrate 4.18
|
||||
get adc.multiplier
|
||||
battery calibrate reset
|
||||
```
|
||||
|
||||
Measure the battery voltage with a voltmeter and enter that reading in volts.
|
||||
The firmware calculates `new multiplier = current multiplier * meter voltage /
|
||||
reported voltage`, applies it and saves it for restart. A reference is required;
|
||||
the command does not assume a chemistry or a 4.2 V full battery. Enter the voltage
|
||||
of the battery input the board actually measures, including pack voltage where
|
||||
that input supports a pack. For example, `battery calibrate 13.2` supplies a
|
||||
13.200 V reference; it does not change the board's measurement range.
|
||||
|
||||
Calibration supports the ESP32, nRF52, RP2040 and STM32 boards with implemented
|
||||
battery-voltage ADC conversions, including the Wio Tracker L2's external ADS1115.
|
||||
An unsupported board or unavailable/saturated reading returns an error. Digital
|
||||
PMU/fuel-gauge and battery-module readings retain their hardware scaling; boards
|
||||
without a battery-voltage input cannot be calibrated through this command.
|
||||
|
||||
The meter reference must be within 50% of the reported voltage. Newly supported
|
||||
ADCs accept a relative multiplier from `0.500` to `1.500`, where `1.000` retains
|
||||
their original conversion. Existing board-specific absolute multipliers and
|
||||
saved values keep their established meaning. The five legacy absolute drivers
|
||||
are Heltec V4, V4 R8, RC32, Meshnology W12 and ProMicro.
|
||||
|
||||
`battery calibrate reset` restores and saves the board's default conversion.
|
||||
`set adc.multiplier 0` also resets it. A successful numeric calibration reply shows the effective
|
||||
multiplier, including any rounding by the board. A failed save reports an error
|
||||
and attempts to restore the previous runtime setting.
|
||||
|
||||
Calibration corrects voltage reporting and the battery percentages/protection
|
||||
that use that reading. On nRF52 boards with voltage policy it also applies to
|
||||
the boot reading and running cutoff. It does not adjust charger hardware or
|
||||
create a current measurement. This is a single-point scale correction, not an
|
||||
ADC offset or nonlinear calibration.
|
||||
|
||||
#### Fine-tune the battery reading
|
||||
**Usage:**
|
||||
- `get adc.multiplier`
|
||||
@@ -2536,13 +2579,16 @@ sessions. Setting the password to `off` makes it the literal password `off`.
|
||||
|
||||
**Default:** `0.0` (value defined by board)
|
||||
|
||||
**Note:** On nRF52 boards with power management and a boot-voltage setting,
|
||||
**Note:** On newly supported ADC boards this is a relative `0.500`-`1.500`
|
||||
correction, with `0` restoring the default. Existing absolute-multiplier boards
|
||||
retain their coefficient units and accept `0` or a positive value up to `10`.
|
||||
On nRF52 boards with power management and a boot-voltage setting,
|
||||
this is a saved *relative* calibration: `1.000` keeps the board conversion,
|
||||
`1.050` raises all reported battery millivolts by 5%, and `0` resets to
|
||||
`1.000`. The allowed range is `0.500`-`1.500`. This affects boot protection,
|
||||
running cutoff, telemetry, battery alerts, and percentage. Calibrate against a
|
||||
voltmeter before enabling a low cutoff. Other boards retain their existing
|
||||
board-specific multiplier behavior, or return unsupported.
|
||||
voltmeter before enabling a low cutoff. Boards without a supported ADC return
|
||||
unsupported.
|
||||
|
||||
---
|
||||
|
||||
|
||||
Reference in new issue