feat(webconfig): let the portal discover board-specific CLI commands
The FEM commands moved out of CommonCLI into Board::handleCommand(), and the T-Beam 1W fan control was added there too, but the portal never caught up: `radio.fem.txgain` and the fan commands were missing from the terminal table entirely, while `radio.fem.rxgain` was offered on every board even though a board with no hook now answers "??:" rather than "unsupported". Whether a node answers these is a property of the board, not of the build, so the page cannot know from the firmware version. Ask the board instead: probeBoardCommands() runs each candidate getter once on the loop task at startup and keeps the ones that answer, which needs no per-variant list because Board::handleCommand() already reports whether it handled a command. /api/status names the survivors and the page hides everything else, so adding a command to a variant means one entry in WC_BOARD_CMDS rather than an edit per board. The two FEM keys also become Radio-panel toggles, gated the same way; their `set` reaches the board hook through the existing config batch, so only the allowlist and /api/config needed to grow. webconfig_cli_audit.py now scans variants/*/*Board.cpp for the boards that actually build the portal, checks set-only keys in the reverse direction, and verifies every gate is a command some board answers; the mock gained --board-cmds so both shapes of board are testable. `stop ota` joins NOT_OFFERED: `start ota` cannot run from the portal, so it has nothing to stop.
This commit is contained in:
1 parent
8c8199a2ea
commit
a1f3e2c3d3
8 files changed
+319
-41
No files matched your search
@@ -322,6 +322,27 @@ Elsewhere it replies `Err - neighbors not enabled in this build`. If a
|
||||
|
||||
---
|
||||
|
||||
#### View the fan state, or change how it is driven, on supported boards
|
||||
**Usage:**
|
||||
- `get fan`
|
||||
- `set fan <mode>`
|
||||
- `set fan.lo <celsius>`
|
||||
- `set fan.hi <celsius>`
|
||||
|
||||
**Parameters:**
|
||||
- `mode`: `on`|`off`|`auto`
|
||||
- `celsius`: `fan.lo` is 0-100 and must be below `fan.hi`; `fan.hi` is at most 120 and must be above `fan.lo`
|
||||
|
||||
**Default:** `auto`, with `fan.lo` 45 and `fan.hi` 60
|
||||
|
||||
**Notes:**
|
||||
- Currently the T-Beam 1W, the only board with a fan under software control.
|
||||
- `get fan` reports the mode, the measured temperature, whether the fan is running, and the remaining cooldown, e.g. `auto 52.4C fan=on cd=18s`. The temperature reads `n/a` when the NTC value is implausible.
|
||||
- In `auto` the fan starts at `fan.hi` and stops at `fan.lo`; the gap between them is what keeps it from chattering around one threshold.
|
||||
- `fan.lo` and `fan.hi` are set-only: `get fan` reports the mode and current state, not the thresholds.
|
||||
|
||||
---
|
||||
|
||||
### System
|
||||
|
||||
#### View or change this node's name
|
||||
|
||||
Reference in new issue