fix(network): harden Ethernet-preferred lifecycle
This commit is contained in:
1 parent
d9db3e8e6a
commit
a0188bd174
26 files changed
+803
-193
No files matched your search
@@ -1276,16 +1276,27 @@ void CommonCLI::handleCommand(uint32_t sender_timestamp, char* command, char* re
|
||||
(int)mi.fordblks, (int)mi.uordblks, (int)mi.arena, (int)mi.ordblks,
|
||||
_callbacks->getQueueSize());
|
||||
#endif
|
||||
} else if (memcmp(command, "start ota", 9) == 0) {
|
||||
} else if (memcmp(command, "start ota", 9) == 0 &&
|
||||
(command[9] == 0 || command[9] == ' ')) {
|
||||
// Manual OTA: bring up the ElegantOTA web UI for a hand-uploaded binary.
|
||||
// Plain "start ota" serves on the station IP when joined to WiFi, else
|
||||
// raises the MeshCore-OTA SoftAP. "start ota ap" forces the SoftAP even
|
||||
// when connected, so the UI is reachable when the network applies client
|
||||
// isolation and the station IP can't be reached. (&& short-circuits keep
|
||||
// the [10]/[11] reads in-bounds when command == "start ota".)
|
||||
bool force_ap = (command[9] == ' ' && command[10] == 'a' && command[11] == 'p');
|
||||
if (!_board->startOTAUpdate(_prefs->node_name, reply, force_ap)) {
|
||||
strcpy(reply, "Error");
|
||||
// isolation and the station IP can't be reached.
|
||||
bool force_ap = command[9] == ' ' && strcmp(&command[10], "ap") == 0;
|
||||
if (command[9] == ' ' && !force_ap) {
|
||||
strcpy(reply, "ERR: usage start ota [ap]");
|
||||
} else {
|
||||
reply[0] = 0;
|
||||
if (!_board->startOTAUpdate(_prefs->node_name, reply, force_ap) &&
|
||||
reply[0] == 0) {
|
||||
strcpy(reply, "Error");
|
||||
}
|
||||
}
|
||||
} else if (strcmp(command, "stop ota") == 0) {
|
||||
reply[0] = 0;
|
||||
if (!_board->stopOTAUpdate(reply) && reply[0] == 0) {
|
||||
strcpy(reply, "ERR: OTA web server not running");
|
||||
}
|
||||
} else if (memcmp(command, "clock", 5) == 0) {
|
||||
uint32_t now = getRTCClock()->getCurrentTime();
|
||||
|
||||
Reference in new issue
Block a user