Add scheduled telemetry history packets

This commit is contained in:
mikecarper committed 2026-08-13 00:52:17 -07:00
1 parent c0aeb8fc3a
commit 8ffafddd6a
7 files changed
+588 -7

No files matched your search

+56 -4
View File
@@ -306,10 +306,11 @@ refresh is already in flight, the scope pass is queued behind it.
### Read repeater telemetry history
Repeater firmware records one UTC-aligned sample every 30 minutes. Temperature
and battery voltage retain 336 samples (seven rolling days). GPS retains three
days by default. Sensor builds with an onboard GPS provider request a seven-day
default at startup. The history and any runtime retention change are held in
RAM and reset after a reboot.
and battery voltage retain 336 samples (seven rolling days). GPS-capable builds
retain three GPS days by default and request a seven-day default at startup.
Builds without a GPS provider omit the GPS history commands to conserve flash.
The history and any runtime retention change are held in RAM and reset after a
reboot.
The feature is omitted from flash-constrained STM32 repeater images.
@@ -319,6 +320,10 @@ The feature is omitted from flash-constrained STM32 repeater images.
- `get telemetry.volt [page]`
- `get telemetry.gps [page]`
- `set telemetry.gps <days>`
- `get telemetry.tx`
- `set telemetry.tx <off|direct|path>`
- `set telemetry.tx schedule <off|1-30d>`
- `send telemetry.tx now`
**Parameters:**
@@ -331,6 +336,12 @@ The feature is omitted from flash-constrained STM32 repeater images.
needed to leave at least 2048 bytes free and replies with the days and pages
actually available. For example, a request can return
`OK - telemetry.gps days=18 pages=36 requested=30`.
- `direct`: Send the binary temperature and voltage snapshots zero-hop to a
neighboring MQTT observer.
- `path`: A comma-separated direct route using the same one-, two-, or
three-byte hop hashes accepted by `set outpath`.
- `schedule`: Automatic interval in whole days. The default is `2d`; `off`
retains the configured direct path for manual test sends.
Local serial and remote administrator CLI sessions can read the history.
Collection uses the MCU temperature, battery voltage, and an already-valid
@@ -345,6 +356,47 @@ Use the browser-based [Telemetry history decoder](telemetry_decoder.md) to
turn a reply into a timestamped table or downloadable CSV without uploading
the data.
`telemetry.tx` is disabled by default. Its schedule and direct path are stored
across reboots. Configuring `direct` or a routed path enables the default `2d`
schedule; `set telemetry.tx schedule` changes it from one through 30 days or
turns it off. An automatic run waits until 165 half-hour positions are
available, then sends one maximum-size temperature packet and one maximum-size
voltage packet. GPS is never included in this raw transmission. The history
remains boot-local, so the first scheduled pair after a reboot needs about
82.5 hours to fill. On the default two-day interval, each 82.5-hour packet
overlaps the previous packet by 34.5 hours. A queue failure is retried after
30 minutes only for the packet that did not queue; successfully queued packets
are not duplicated.
`send telemetry.tx now` is an administrator-only test action. It immediately
queues one temperature and one voltage direct packet over the configured path,
using all currently available positions up to 165. It works while the schedule
is off and does not move the next scheduled send time. RAW_CUSTOM direct
packets do not enter the normal encrypted direct-message retry mechanism.
Full snapshots are 184-byte RAW_CUSTOM payloads. Manual tests can be shorter
while history fills. Both formats are binary, not Base64 and not encrypted:
| Bytes | Meaning |
|---|---|
| `0`-`3` | ASCII magic `TTB1` for temperature or `TVB1` for voltage |
| `4`-`11` | First eight bytes of the repeater public key |
| `12`-`15` | First sample UTC epoch, unsigned 32-bit little-endian |
| `16`-`17` | Sample interval in minutes, unsigned 16-bit little-endian (`30`) |
| `18` | Sample count (`1`-`165`) |
| `19` onward | Oldest-to-newest encoded samples for the selected series |
Temperature codes reserve `0` for no reading, `1` for below `-50 C`, and `2`
for above `+77 C`. Codes `3` through `130` represent exact whole degrees from
`-50 C` through `+77 C`; decode them as `code - 53`. Voltage codes use the
same encoding as the paged voltage payload documented below.
Match bytes `4`-`11` to the first 16 hex characters of the repeater public key
shown by its advert or `get public.key`. This compact identifier is useful for
association but is not authenticated and can be spoofed. An MQTT observer can
upload the received raw packet to LetsMesh Analyzer `/packets`; its packet hex
contains the direct-route header and path followed by this payload.
Temperature payload (`0x11`, 61 bytes):
| Bytes | Meaning |