Fix W12 TX prearming without standby PA drain
This commit is contained in:
1 parent
f1d281a766
commit
8874cf62ca
9 files changed
+747
-10
No files matched your search
@@ -153,3 +153,22 @@ Nano G2 Ultra, ThinkNode M1/M8 and Keepteen LT1 retain their plain `NRF52Board`
|
||||
initializers for the same reason. The MeshTracker X1's LR2021 regulator likewise
|
||||
remains unchanged. Do not turn on a switching regulator without its required
|
||||
inductor/capacitor network. The MCU and LoRa regulator choices are independent.
|
||||
|
||||
## Meshnology W12 transmit preparation
|
||||
|
||||
The W12 adopts the GC1109 TX preparation from
|
||||
[upstream PR #3579](https://github.com/meshcore-dev/MeshCore/pull/3579), but keeps
|
||||
the PA shut down in ordinary standby rather than permanently selecting TX mode.
|
||||
Before sub-GHz packet or Morse CW transmission, it temporarily enables the LF
|
||||
PA in standby, waits 1 ms, starts TX, then restores the normal standby mask.
|
||||
The TX mask stays unchanged during that restoration. Failure paths restore all
|
||||
affected DIOs and request radio recovery if the PA state cannot be confirmed.
|
||||
The 2.4 GHz path and other LR2021 boards do not use this LF prearm policy.
|
||||
|
||||
LF/HF FEM rail changes now settle for 1 ms instead of 100 ms. Packet-wake deep
|
||||
sleep retains only the selected FEM rail; terminal shutdown retains both rails
|
||||
off. This is separate from the W12's existing circuit-verified DC/DC setting.
|
||||
|
||||
Native fault-injection tests cover the mask transitions and power retention;
|
||||
RF envelope and battery-current measurements on a physical W12 are still needed
|
||||
to validate the TX improvement and quantify power use.
|
||||