Retain independent RS232 in Full MQTT repeaters

This commit is contained in:
mikecarper committed 2026-10-05 18:21:42 -07:00
1 parent 292834c9b1
commit 6765100c3a
37 files changed
+1572 -196

No files matched your search

+12
View File
@@ -204,6 +204,18 @@ available from a canonical image:
target remains directly buildable with its bridge-on default but is omitted
from bulk releases. Browser OTA pauses ESP-NOW while leaving RS-232 running;
`stop ota` restores ESP-NOW when its saved setting is on.
- Full Heltec V3, Wireless Stick Lite V3, RAK3112 and LilyGo T-LoRa V2.1-1.6
MQTT repeaters retain RS-232 alongside MQTT and ESP-NOW. The first three
use UART2 with RX on GPIO5 and TX on GPIO6; T-LoRa uses UART2 with RX on
GPIO34 and TX on GPIO25. Use `set rs232.enabled on|off` and
`get rs232.running` independently of `mqtt.enabled` and `espnow.enabled`.
`bridge.baud` and `bridge.uart` configure the UART. Old MQTT preferences
do not enable this newly added UART; its saved intent needs a validated
UART profile marker. Historical `bridge.enabled` keeps its ESP-NOW meaning
in MQTT images and its UART meaning in non-MQTT images. Full qualification
verifies the linked UART driver even when compiling observer sources for a
normal repeater, and resumed release selection rejects Full images without
that proof.
- MeshTower V2 repeaters use
`Heltec_tower_v2_sdcard_repeater_lora_ota_no_external_sensors` as the one
canonical target. Its SD OTA target `0A9DBBF0`, hardware ID