Preserve admin password input and clarify reconnect guidance

This commit is contained in:
mikecarper committed 2026-10-18 13:45:13 -07:00
1 parent ad4124b055
commit 5d741318f5
15 files changed
+2858 -2334

No files matched your search

+41 -17
View File
@@ -876,13 +876,23 @@ After this bootloader is flashed onto the device, you can trigger an over-the-ai
filename).
2. From the MeshCore app, log in remotely to the repeater you want to update with admin privileges.
3. Go to the Command Line tab, type `start ota` and hit enter.
4. The reply confirms WiFi is on and gives the OTA upload URL and network to use.
5. If the ESP32 is not already joined to Wi-Fi, `start ota` starts an open hotspot named `MeshCore-OTA` at `192.168.4.1`. If it is already joined, the command reports and uses its router-assigned address instead.
6. From your phone or computer, connect to the `MeshCore-OTA` hotspot when one was started.
7. Open the URL reported by `start ota` and upload the non-merged bin from the flasher. When the device started `MeshCore-OTA`, the URL is <http://192.168.4.1/update>.
4. The reply gives the OTA upload URL, network to use, and HTTP login details.
5. If the ESP32 is not already joined to Wi-Fi, `start ota` starts the
`MeshCore-OTA` hotspot at `192.168.4.1`. It uses the node's admin password for
WPA2 when that password is 8–15 printable ASCII characters. Other accepted
admin passwords leave the hotspot open; the HTTP login still applies. If
the node is already joined, the command uses its router-assigned address.
6. From your phone or computer, join `MeshCore-OTA` when one was started. Use
the node's admin password if the WiFi connection asks for a password.
7. Open the exact URL reported by `start ota`. Sign in with HTTP Basic username
`admin` and the node's current admin password, then upload the non-merged
application bin from the flasher. The URL normally uses port 80, or port
8080 on Full Companion builds with browser OTA support.
`start ota` automatically stops WebConfig and reports the change; both servers
use HTTP port 80. Stop the OTA uploader before running `start webconfig` again.
`start ota` automatically stops WebConfig and reports the change. Stop the OTA
uploader before running `start webconfig` again. Temporary partition-migration
and recovery applications retain their documented access policy. See the
[WiFi guide](WiFi.md) for the shared admin-password policy.
### 7.3. Q: Is there a way to lower the chance of a failed OTA device firmware update (DFU)?
@@ -925,22 +935,36 @@ Where `&type` is:
### 7.6. Q: How do I connect to the companion via Wi-Fi, e.g. using a Heltec V3?
**A:**
Flash an ESP32 companion Wi-Fi build. Its shared WebUI is enabled by default. If
it has no saved Wi-Fi configuration, it starts an open `MeshCore-Setup-XXXX`
access point. Join it and browse to <http://192.168.4.1/>. The wizard configures
WiFi, node identity, and radio settings; MQTT companion builds add an MQTT step
and MQTT tab, while non-MQTT companions remove those controls. After saving,
the page and device screen show the station IP assigned by your router.
it has no saved Wi-Fi configuration, it starts a `MeshCore-Setup-XXXX` access
point. The hotspot uses the node's admin password for WPA2 when it is 8–15
printable ASCII characters; standard builds initially use `password`. Other
accepted admin passwords leave the hotspot open and require an HTTP admin
login. Join it and browse to <http://192.168.4.1/>. Protected first-time setup
continues directly to the wizard, which configures WiFi, node identity, radio,
and the admin password. MQTT companion builds add an MQTT step and tab, while
non-MQTT companions remove those controls. After saving, the page and device
screen show the station IP assigned by your router.
If a saved network remains unreachable for two minutes, the setup AP starts as
a fallback. If the original network returns, the companion closes that recovery
portal and resumes normal LAN operation.
a fallback. Sign in with the existing admin password before changing settings
on that recovery page. If the original network returns, the companion closes
the recovery portal and resumes normal LAN operation.
The setup AP always uses `192.168.4.1`; the companion's station IP is assigned by DHCP and can be different. A real `WIFI_SSID` and `WIFI_PWD` can still be supplied at compile time as initial defaults, but they are no longer required.
On the LAN, the WebUI remains available at the companion's station IP and the
companion protocol remains available on TCP port `5000`. Companion builds do not
have an admin CLI password, so this configuration page trusts the local LAN; do
not put the companion on an untrusted WiFi network.
On the LAN, sign in to the WebUI at the companion's station IP with its saved
admin password. ESP32 WiFi Companions share that password between WebConfig,
protected setup WiFi, and runtime browser OTA; other Companion builds retain
their existing no-admin-password behavior. Change it with
`password <new-password>` on USB or another available administrative connection.
An ESP32 WiFi Companion's password is stored in NVS and survives a filesystem
erase; `get password` reports its availability without revealing it. If it
reports an unavailable management password, set a new one over USB to repair it.
The Companion protocol on TCP port `5000` retains its trusted-network policy;
the browser login does not protect that port. Use a trusted WiFi network. Router
WiFi passwords, MQTT credentials, and Bluetooth PINs remain separate. See the
[WiFi guide](WiFi.md) for password-change and reconnect behavior.
ESP32 repeater and room-server builds use the same page, but keep it off by
default. Run `set webui on` from the admin CLI, open the reported LAN URL, and