fix: stabilize Heltec RC32 startup

This commit is contained in:
mikecarper committed 2026-08-27 17:06:20 -07:00
1 parent 7676e4b1c2
commit 5a26d4ddd1
10 files changed
+95 -9

No files matched your search

+14
View File
@@ -92,9 +92,23 @@ class CustomSX1262 : public SX1262 {
#endif
int status = begin(LORA_FREQ, LORA_BW, LORA_SF, cr, RADIOLIB_SX126X_SYNC_WORD_PRIVATE, LORA_TX_POWER, 16, tcxo, useRegulatorLDO);
if (status != RADIOLIB_ERR_NONE) {
#if defined(SX126X_ALLOW_RECOVERABLE_INIT_STATUS) && SX126X_ALLOW_RECOVERABLE_INIT_STATUS
// Some SX1262 modules report a transient command status after the
// chip has already answered its identity probe. Continue configuring
// those devices; an absent chip or a hard command failure is fatal.
if (status == RADIOLIB_ERR_CHIP_NOT_FOUND
|| status == RADIOLIB_ERR_SPI_CMD_FAILED) {
mesh::usbLoggingPort().print("ERROR: radio init failed: ");
mesh::usbLoggingPort().println(status);
return false;
}
mesh::usbLoggingPort().print("WARN: recoverable radio init status: ");
mesh::usbLoggingPort().println(status);
#else
mesh::usbLoggingPort().print("ERROR: radio init failed: ");
mesh::usbLoggingPort().println(status);
return false; // fail
#endif
}
// RadioLib's default DIO3 TCXO delay is 5 ms and its RX duty-cycle