feat(webconfig): implement /api/cli on the device
The terminal has been driving the mock since it was built. This is the firmware
side, so it works on hardware.
Same 202 + reqid + poll contract as a config save, for the same reason:
CommonCLI touches prefs, the radio and the filesystem, none of which may be
reached from the async_tcp task. Commands go into the deferred slot and tick()
drains them on the loop task. Unlike a save this is not allowlisted — reaching
what the serial console reaches is the point, and execCommand() already passes
sender_timestamp 0, so the terminal gets exactly the serial console's
privilege. Authentication is the boundary, as it is there.
The CLI shares the config batch's slot rather than owning a second MAX_BATCH
array: both drain on the loop task, both are single-slot, and a duplicate would
cost ~8 KB of permanently resident RAM. Sharing also makes a save and a CLI run
mutually exclusive, which they must be. Each reader checks the kind, so neither
can serve the other's results.
Three things the mock could not have taught us:
- Board::reboot() does not return, so a drained `reboot` would take the node
down before the client read a single result. It is answered rather than
executed, and the batch arms the existing deferred-reboot path once the
results have been read — withheld if any command failed, exactly as a save
withholds one. clkreboot/poweroff/ota update do real work on the way down
and cannot be faked, so they still drop the connection; the UI warns first.
- `password <new>` echoes the new password in its reply. The config path
already scrubbed that by key; a CLI entry has no key, so it is matched on
the command. CLI commands are also kept out of the serial log entirely —
the browser session and the serial console are different audiences.
- MAX_BATCH is 24, not the 64 the page assumed. It is reported as
status.max_cmds instead of hardcoded, so the cap cannot drift.
Results stream and page (kCliResultPage = 8), and "done" means the client has
been handed every result, not merely that execution finished — otherwise a
client that stops polling at "done" loses the last page. Commands are never
echoed back: they may carry a secret, and the client matches by index.
New decisions live in WebConfigBatch.h with the rest, covered by three host
tests. Builds clean for heltec_v4_repeater_observer_mqtt; 22 batch + 14 keys
tests pass; the CLI audit reports 119/119 against the updated mock.
This commit is contained in:
1 parent
58b8b90560
commit
556d02f765
7 files changed
+446
-37
No files matched your search
+32
-11
@@ -626,6 +626,7 @@ function boot(){
|
||||
// (active_slots: 2 without PSRAM, 5 with). Fall back to the runtime array
|
||||
// size for older firmware that doesn't report it.
|
||||
st.mode=s.mode;st.authed=s.auth;st.needsSetup=!!s.needs_setup;st.nslots=s.active_slots||s.runtime_slots||6;
|
||||
if(s.max_cmds>0)CLI_MAX=s.max_cmds;
|
||||
$("#h-name").textContent=s.name||"MeshCore";
|
||||
$("#h-sub").textContent=s.role+" · "+s.fw+" · "+s.board;
|
||||
var b=$("#h-badge");b.classList.remove("hide");
|
||||
@@ -1428,7 +1429,10 @@ function showReboot(msg,reconnect,title){
|
||||
Drives autocomplete only — the node remains the authority on what it accepts.
|
||||
A trailing space marks a command that takes an argument, so accepting the
|
||||
completion leaves the cursor ready for the value. */
|
||||
var CLI_MAX=64; // commands per submitted sequence
|
||||
// Commands per submitted sequence. The node reports its own limit (MAX_BATCH,
|
||||
// the fixed slot the CLI shares with config saves) in /api/status; this is only
|
||||
// the fallback for firmware that doesn't say.
|
||||
var CLI_MAX=24;
|
||||
// [command, description]
|
||||
var CLI_VERBS=[
|
||||
["ver","Firmware version"],
|
||||
@@ -1967,13 +1971,17 @@ function cliPoll(reqid,cmds,from,status,errs,idles){
|
||||
if(idles<5){setTimeout(function(){cliPoll(reqid,cmds,from,status,errs,idles+1)},400);return}
|
||||
cliEnd(status,"The node never received the command.");return;
|
||||
}
|
||||
(r.results||[]).forEach(function(x){
|
||||
cliEcho("cmd",x.cmd);
|
||||
(r.results||[]).forEach(function(x,i){
|
||||
// The node never echoes the command back — it may hold a password or a
|
||||
// token, and we already have the sequence we sent. Match by index.
|
||||
cliEcho("cmd",cmds[from+i]||"");
|
||||
// `ok` is advisory; the node's own OK/Error convention is authoritative
|
||||
var ok=(x.ok!=null)?x.ok:!/^\s*(err|error)\b/i.test(x.reply||"");
|
||||
if(x.reply)cliEcho(ok?"rep":"err",x.reply);
|
||||
});
|
||||
from+=(r.results||[]).length;
|
||||
// "running" also covers "finished, but more results are still to be paged
|
||||
// over", so keep polling until the node says done.
|
||||
if(r.state!=="done"){
|
||||
if(cmds.length>1)status.textContent="running "+from+"/"+cmds.length+"…";
|
||||
setTimeout(function(){cliPoll(reqid,cmds,from,status,0,0)},250);
|
||||
@@ -1981,7 +1989,7 @@ function cliPoll(reqid,cmds,from,status,errs,idles){
|
||||
}
|
||||
status.remove();
|
||||
cliBusy(false);
|
||||
cliAfter(cmds);
|
||||
cliAfter(cmds,r);
|
||||
}).catch(function(e){
|
||||
if(e.message==="auth"){cliBusy(false);status.remove();return}
|
||||
if(e.status===400||e.status===404){cliEnd(status,"The node no longer has a result for this sequence.");return}
|
||||
@@ -1991,18 +1999,31 @@ function cliPoll(reqid,cmds,from,status,errs,idles){
|
||||
}
|
||||
// A CLI `set` writes the same prefs the forms edit, so re-read them or the
|
||||
// other tabs keep showing stale values.
|
||||
function cliAfter(cmds){
|
||||
var touched=false,restart=null;
|
||||
function cliAfter(cmds,r){
|
||||
var touched=false;
|
||||
cmds.forEach(function(c){
|
||||
if(/^password\s/.test(c))cli.pwd=true;
|
||||
if(/^(set|password)\s/.test(c))touched=true;
|
||||
if(/^(reboot|clkreboot)$/.test(c))restart=restart||"reboot";
|
||||
if(/^erase$/.test(c))restart=restart||"erase";
|
||||
if(/^(poweroff|shutdown)$/.test(c))restart="off";
|
||||
});
|
||||
if(touched)loadConfigSoft();
|
||||
if(restart==="off")showReboot("The node is powering off. Reconnect power to bring it back.",false,"Powering off…");
|
||||
else if(restart)showReboot("The node is restarting. This page will try to reconnect automatically.",true);
|
||||
// A `reboot` in the sequence is not run by the CLI — Board::reboot() never
|
||||
// returns, so the node answers it and schedules the restart for after this
|
||||
// read. It withholds it when any command failed, exactly as a config save
|
||||
// does; say which happened rather than leaving the operator to guess.
|
||||
if(r&&r.reboot_withheld){
|
||||
cliEcho("err","Not rebooting — some commands failed. Fix them and run \"reboot\" again.");
|
||||
return;
|
||||
}
|
||||
if(r&&r.reboot){
|
||||
showReboot("The node is restarting. This page will try to reconnect automatically.",true);
|
||||
return;
|
||||
}
|
||||
// clkreboot / poweroff / erase-and-flash take the node down themselves, so
|
||||
// there is no result to wait for.
|
||||
cmds.forEach(function(c){
|
||||
if(/^(poweroff|shutdown)$/.test(c))showReboot("The node is powering off. Reconnect power to bring it back.",false,"Powering off…");
|
||||
else if(/^clkreboot$/.test(c))showReboot("The node is restarting. This page will try to reconnect automatically.",true);
|
||||
});
|
||||
}
|
||||
|
||||
/* ---------- CLI: fit ----------
|
||||
|
||||
Reference in new issue
Block a user