Fix LoRa OTA TempRadio compatibility and lease handling

Accept preamble-bearing TempRadio status from newer firmware while retaining legacy replies. Keep the 20-minute hard minimum but make the 120-minute and timeout estimates advisory, with a window-only override. Add parser, rehearsal, relay identity, and RAK bootloader regression coverage.
This commit is contained in:
mikecarper committed 2026-09-29 07:48:01 -07:00
1 parent 84429ae520
commit 21d42aa57f
6 files changed
+243 -58

No files matched your search

+7
View File
@@ -479,6 +479,13 @@ The lab test default is 909.5 MHz, 500 kHz bandwidth, SF5, and CR5. The frequenc
North American example: choose a legal frequency supported by every
participating radio and appropriate to your location. Older radios that do not
support SF5 require a complete replacement tuple passed with `--temp-radio`.
The fifth value is the TempRadio window in minutes. To change only that value,
pass `--temp-radio-minutes 90`; this works with `--relay` and keeps the chosen
frequency, bandwidth, SF, and CR. The hard minimum is 20 minutes. The 120-minute
default and the runner's worst-case timeout estimate are guidance. A window
below the estimate prints a warning and continues; the radio lease can expire
before a slow OTA finishes.
The separate three-minute path rehearsal and its identity checks still run.
Before that long window is allowed, the live runner performs a mandatory
independent three-minute rehearsal. Its exact normal-channel `ota status` and