-8
@@ -3024,8 +3024,8 @@ send text.flood checking ridge link
|
||||
- `set battery.alert.critical <0-99>`
|
||||
|
||||
**Defaults:**
|
||||
- `battery.alert.low`: `20`
|
||||
- `battery.alert.critical`: `10`
|
||||
- `battery.alert.low`: `25`
|
||||
- `battery.alert.critical`: `15`
|
||||
|
||||
**Note:** The low threshold must be greater than the critical threshold. Alerts at or below the critical threshold use `CRITICAL BATTERY` in the message; both severities use the same 12-hour resend cooldown.
|
||||
|
||||
@@ -3052,12 +3052,17 @@ readings remain available.
|
||||
- `set flood.battery <off|on|1-100>`
|
||||
- `get battery.forward`
|
||||
|
||||
`set repeat.battery on` enables the saved repeat threshold, initially **10%**.
|
||||
`set flood.battery on` enables the saved flood threshold, initially **20%**.
|
||||
`set repeat.battery on` enables the saved repeat threshold, initially **15%**.
|
||||
`set flood.battery on` enables the saved flood threshold, initially **25%**.
|
||||
A number both enables the control and sets its threshold. `off` disables it
|
||||
while retaining that threshold for the next `on`. Changes are saved and take
|
||||
effect without a reboot.
|
||||
|
||||
An older forwarding record with exactly the former 10% repeat / 20% flood
|
||||
defaults adopts 15% / 25% on upgrade. Its enabled controls and voltage endpoints
|
||||
stay unchanged. Other saved thresholds are retained; newly selected custom
|
||||
10% / 20% settings also remain available.
|
||||
|
||||
Below the repeat threshold, the node stops LoRa retransmissions of received
|
||||
traffic. Below the flood threshold, it stops LoRa retransmissions of received
|
||||
flood traffic but may still
|
||||
@@ -3071,8 +3076,8 @@ limits. Exporting radio reception to WiFi, ESP-NOW, or RS232 is unchanged.
|
||||
|
||||
Forwarding resumes automatically after the measured percentage reaches two
|
||||
percentage points above the applicable threshold, capped at 100%. With the
|
||||
initial thresholds, flood forwarding pauses below 20% and resumes at 22%; all
|
||||
relay forwarding pauses below 10% and resumes at 12%. This recovery margin
|
||||
initial thresholds, flood forwarding pauses below 25% and resumes at 27%; all
|
||||
relay forwarding pauses below 15% and resumes at 17%. This recovery margin
|
||||
avoids repeatedly switching forwarding on and off near a threshold.
|
||||
|
||||
Battery voltage is sampled every 30 seconds while either control is enabled,
|
||||
@@ -3093,12 +3098,54 @@ get battery.forward
|
||||
To choose different thresholds and later disable the feature:
|
||||
|
||||
```text
|
||||
set repeat.battery 15
|
||||
set flood.battery 25
|
||||
set repeat.battery 12
|
||||
set flood.battery 22
|
||||
set repeat.battery off
|
||||
set flood.battery off
|
||||
```
|
||||
|
||||
#### Emergency battery schedule
|
||||
|
||||
Supported ESP32 and nRF52 Repeater, Room Server and Sensor images enter the
|
||||
final battery-saving stage at **5% or less**, independently of the optional
|
||||
forwarding gates. Automatic mode returns to normal at **7% or more**. An
|
||||
invalid battery reading cannot activate it, or falsely clear an existing low
|
||||
battery state. Percentage uses the same configured voltage endpoints as
|
||||
`battery.forward`; it does not prove that a physical battery is connected.
|
||||
|
||||
In emergency mode, normal work runs during the first **15 minutes of every
|
||||
UTC hour** (`:00:00` through `:14:59`). For the remaining 45 minutes the LoRa
|
||||
radio sleeps and normal mesh, sensor and screen work is suspended. The CPU
|
||||
uses timed sleep with brief watchdog, clock, voltage-protection and command
|
||||
maintenance wakes. Active firmware updates and unfinished critical operations
|
||||
defer sleep. Existing hard low-voltage protection remains in force.
|
||||
|
||||
```text
|
||||
get power.emergency
|
||||
set power.emergency on
|
||||
set power.awake 30
|
||||
set power.awake 0
|
||||
set power.emergency auto
|
||||
```
|
||||
|
||||
`on` saves manual emergency mode, including across reboots. `auto` restores
|
||||
battery-controlled entry and is the default. The initial transition allows
|
||||
five seconds for its reply. `power.awake` keeps the node up for the next given
|
||||
number of minutes (0 cancels; maximum 10080), even outside the hourly window.
|
||||
That override is held in RAM and ends on reboot; it never disables hard
|
||||
low-voltage shutdown. Use it before maintenance that needs continuous uptime.
|
||||
|
||||
`get power.emergency` reports the mode, battery estimate, desired `window`,
|
||||
actual radio ownership, seconds until the next awake window, and remaining
|
||||
hold. With an unset clock it reports `clock=uptime` and follows the same
|
||||
15/45-minute cycle from boot until a valid UTC clock is available. Queued
|
||||
future traffic does not keep a critically low node awake indefinitely.
|
||||
|
||||
This schedule uses resumable timed sleep, preserving identity and settings.
|
||||
WiFi/ESP-NOW services are temporarily stopped and their previous live subset
|
||||
is restored when the node wakes. Companion builds and flash-constrained
|
||||
profiles that omit battery-forwarding controls do not add this feature.
|
||||
|
||||
#### Set the battery percentage voltage range
|
||||
|
||||
The forwarding thresholds use a voltage-derived percentage. On infrastructure
|
||||
|
||||
@@ -246,6 +246,27 @@ measurement or entry into ship mode. Read the corresponding status afterward.
|
||||
See the [bench acceptance report](test-results/solarxiao_power_2026-10-21.md)
|
||||
for exact firmware identity, measured readouts and test limits.
|
||||
|
||||
## Emergency battery schedule
|
||||
|
||||
The [emergency schedule](cli_commands.md#emergency-battery-schedule) keeps the
|
||||
radio and normal work awake for the first 15 minutes of each UTC hour, with
|
||||
timed sleep for the remaining 45 minutes. It starts automatically at 5% and
|
||||
recovers at 7%. Forwarding thresholds now default to 25% for floods and 15%
|
||||
for all relayed traffic; those forwarding gates remain opt-in.
|
||||
|
||||
```text
|
||||
get power.emergency
|
||||
set power.emergency on
|
||||
set power.awake 30
|
||||
set power.emergency auto
|
||||
```
|
||||
|
||||
The percentage follows the configured self battery voltage endpoints used by
|
||||
`battery.forward`. On MPPT carriers this is the XIAO ADC, not an estimate of
|
||||
the separate carrier battery's charge from INA260/LTC4162. Check the actual
|
||||
voltage source before relying on automatic entry. Manual mode and timed wake
|
||||
work independently of the charger. Hard low-voltage protection still applies.
|
||||
|
||||
## Conversion defaults and carrier revisions
|
||||
|
||||